Direkt zum Inhalt
Merck
  • A multiclass method for the analysis of endocrine disrupting chemicals in human urine samples. Sample treatment by dispersive liquid-liquid microextraction.

A multiclass method for the analysis of endocrine disrupting chemicals in human urine samples. Sample treatment by dispersive liquid-liquid microextraction.

Talanta (2014-08-17)
F Vela-Soria, O Ballesteros, A Zafra-Gómez, L Ballesteros, A Navalón
ZUSAMMENFASSUNG

The population is continuously exposed to endocrine disrupting chemicals (EDCs). This has influenced an increase in diseases and syndromes that are more frequent nowadays. Therefore, it is necessary to develop new analytical procedures to evaluate the exposure with the ultimate objective of establishing, in an accurate way, relationships between EDCs and harmful health effects. In the present work, a new method based on a sample treatment by dispersive liquid-liquid microextraction (DLLME) for the extraction of six parabens (methyl-, ethyl-, isopropyl-, propyl-, isobutyl and butylparaben), six benzophenones (benzophenone-1, benzophenone-2, benzophenone-3, benzophenone-6, benzophenone-8 and 4-hydroxybenzophenone) and two bisphenols (bisphenol A and bisphenol S) in human urine samples, followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis is proposed. An enzymatic treatment allows determining the total content of the target EDCs. The extraction parameters were accurately optimized using multivariate optimization strategies. Ethylparaben ring-(13)C6 and bisphenol A-d16 were used as surrogates. Found limits of quantification ranging from 0.2 to 0.5 ng mL(-1) and inter-day variability (evaluated as relative standard deviation) ranging from 2.0% to 14.9%. The method was validated using matrix-matched standard calibration followed by a recovery assay with spiked samples. Recovery rates ranged from 94% to 105%. A good linearity, for concentrations up to 300 ng mL(-1) for parabens and 40 ng mL(-1) for benzophenones and bisphenols, respectively, was obtained. The method was satisfactorily applied for the determination of target compounds in human urine samples from 20 randomly selected individuals.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Acetonitril, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, for molecular biology
Sigma-Aldrich
Aceton, ACS reagent, ≥99.5%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Ethylacetat, ACS reagent, ≥99.5%
Sigma-Aldrich
Kaliumchlorid, ACS reagent, 99.0-100.5%
Sigma-Aldrich
Aceton, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Acetonitril, HPLC Plus, ≥99.9%
Sigma-Aldrich
Natriumsulfat, ACS reagent, ≥99.0%, anhydrous, granular
Sigma-Aldrich
Ethylacetat, suitable for HPLC, ≥99.7%
Sigma-Aldrich
Aceton, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Natriumsulfat, ACS reagent, ≥99.0%, anhydrous, powder
Sigma-Aldrich
Magnesiumsulfat, anhydrous, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Ethylacetat, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, meets USP testing specifications
Sigma-Aldrich
Calciumchlorid Dihydrat, ACS reagent, ≥99%
Sigma-Aldrich
Acetonitril, ACS reagent, ≥99.5%
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, for molecular biology
Sigma-Aldrich
Acetonitril, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Calciumchlorid Dihydrat, ReagentPlus®, ≥99.0%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Kaliumchlorid, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, E508, 99-100.5% (AT), ≤0.0001% Al
Sigma-Aldrich
Kaliumchlorid, for molecular biology, ≥99.0%
Sigma-Aldrich
Zitronensäure, meets analytical specification of Ph. Eur., BP, USP, E330, anhydrous, 99.5-100.5% (based on anhydrous substance)
Sigma-Aldrich
Tetrachlorkohlenstoff, reagent grade, 99.9%
Sigma-Aldrich
Ammoniumchlorid, ReagentPlus®, ≥99.5%
Supelco
N,O-Bis-(trimethylsilyl)-trifluoracetamid mit Trimethylchlorsilan, with 1% trimethylchlorosilane, for GC derivatization, LiChropur