Direkt zum Inhalt
Merck

Validation of a radial diffusive sampler for measuring occupational exposure to 1,3-butadiene.

Journal of chromatography. A (2014-03-08)
Mariella Carrieri, Giovanni B Bartolucci, Enrico Paci, Paolo Sacco, Daniela Pigini, Laura Zaratin, Danilo Cottica, Maria L Scapellato, Giovanna Tranfo
ZUSAMMENFASSUNG

1,3-Butadiene (BD) is a major industrial chemical used in the manufacture of rubbers and latexes; it is also a ubiquitous environmental pollutant whose major source is traffic. Occupational exposure to (BD) can occur both during its production and during its use as a raw material. The objective of the study was the laboratory and field validation of a new diffusive sampler for BD. The nominal sampling rate of the Radiello diffusive sampler filled with Carbopack X is 30.5 cm(3)/min, at 0.177 mg/m(3), 20 °C and 50% relative humidity (RH), for an 8-h exposure time. A model can be used for calculating the sampling rate as a function of temperature, time and RH. The concentration does not affect the sampling rate above 30 μg/m(3). The measurement uncertainty (k=2), calculated both by laboratory data and by field comparison according to International Standard Organization (ISO) 13752, satisfies the EN 482:2006 requirement for measurements between 0.1 and 0.5 times the threshold limit value-time weighted average (TLV-TWA) (uncertainty<50%). For field validation study, 38 workers exposed to BD and 20 administrative employees, as the control group, underwent environmental and biological monitoring. Personal exposure to BD was measured by diffusive samplers (Radiello) in comparison with active samplers. The BD exposure levels detected for the exposed subjects were low (mean 0.059, range <0.010-1.340 mg/m(3)) but higher than the controls levels, all below 0.010 mg/m(3). The comparison between diffusive and active (pumped) air sampling showed a good correlation, with no systematic deviation from the ideal values of the intercept and slope of the optimized regression line. The concentrations of two biomarkers were also determined on urine samples, collected at the end of the work-shift: unchanged BD, by GC-MS, and the metabolite dihydroxybutylmercapturic acid (DHBMA), by HPLC-MS/MS. The urinary excretion of the biomarkers was on average higher in the exposed group (urinary BD: mean 8.8, range <1-48.1 ng/l; DHBMA: mean 0.232, range 0.016-0.572 mg/l) than in controls (urinary BD: mean 6.4, range 2.6-14.5 ng/l; DHBMA: mean 0.205, range 0.037-0.602 mg/l), but a statistically significant difference was achieved only for unchanged BD and not for DHBMA. In conclusion, the environmental monitoring measured by diffusive samplers (Radiello) appears to be a reliable method for the assessment of exposure to low levels of airborne BD and a convenient alternative to the conventional active sampling.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

radiello Kartuschen-Adsorbenzien, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
radiello Dreieckige Trägerplatte, pk of 20
radiello Diffusionskörper, white, configured for general use, pk of 20
radiello Kartuschen-Adsorbenzien, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20
Supelco
FLM Carbopack X TD-Röhrchen aus deaktiviertem Edelstahl, preconditioned, pkg of 10 tubes, O.D. × L 1/4 in. (6.35 mm) × 3 1/2 in. (89 mm)
radiello Kartuschen-Adsorbenzien, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
radiello Diffusionskörper, blue, configured for sampling light sensitive compounds, pk of 20
radiello Diffusionskörper, yellow, configured for reduced sampling rates, pk of 20
Supelco
Carbopack Adsorbens, matrix Carbopack B, 60-80 mesh, bottle of 10 g
radiello Kartuschen-Adsorbenzien, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
Supelco
Carbopack Adsorbens, matrix Carbopack C, 80-100 mesh, bottle of 10 g
Supelco
Carbopack Adsorbens, matrix Carbopack C, 60-80 mesh, bottle of 10 g
Supelco
radiello Methylenblau-Kalibrierstandard für H2S (Schwefelwasserstoff), pkg of 100 mL
radiello Freiluft-Schutzvorrichtung, pk of 10
Supelco
Carbopack Adsorbens, matrix Carbopack X, 40-60 mesh, bottle of 10 g
radiello Strichcode-Etiketten, pk of 198
Supelco
Carbopack B, O.D. × L 1/4 in. × 3 1/2 in., glass TD tube, fritted, Sealed with Brass Endcaps, preconditioned, pkg of 10 ea
radiello Vertikaler Adapter, threaded for standard use, pk of 20
radiello BTEX/VOC Starter Kit, CS2 Desorption
radiello Filtrations-Kit, pk of 20
radiello BTEX/VOC Starter Kit, Thermal Desorption
Supelco
Carbopack Adsorbens, matrix Carbopack X, 60-80 mesh, bottle of 10 g
Supelco
radiello BTEX-Kalibrierkit (Thermische Desorption)
radiello Hydrogen Sulfide Starter Kit
radiello Feld-Thermometer, Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3
Supelco
Carbopack B, stainless steel TD tube, O.D. × L 1/4 × 3 1/2, unconditioned, pkg of 10 ea
radiello Kartuschen-Adsorbenzien, pkg of 20 ea
Supelco
Supelclean ENVI-Carb X SPE Bulk-Packung, matrix Carbopack X, 120-400 mesh, bottle of 50 g
radiello Anesthetic Gases and Vapor Sampler
radiello Leerröhrchen zur Aufbewahrung, glass (with stopper), volume 2.8 mL, pk of 100