Direkt zum Inhalt
Merck
  • Rapid determination of thiamine, riboflavin, niacinamide, pantothenic acid, pyridoxine, folic acid and ascorbic acid in Vitamins with Minerals Tablets by high-performance liquid chromatography with diode array detector.

Rapid determination of thiamine, riboflavin, niacinamide, pantothenic acid, pyridoxine, folic acid and ascorbic acid in Vitamins with Minerals Tablets by high-performance liquid chromatography with diode array detector.

Journal of pharmaceutical and biomedical analysis (2012-07-13)
Pengfei Jin, Lufeng Xia, Zheng Li, Ning Che, Ding Zou, Xin Hu
ZUSAMMENFASSUNG

A simple, isocratic, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed for the rapid determination of thiamine (VB(1)), niacinamide (VB(3)), pyridoxine (VB(6)), ascorbic acid (VC), pantothenic acid (VB(5)), riboflavin (VB(2)) and folic acid (VB(9)) in Vitamins with Minerals Tablets (VMT). An Alltima C(18) column (250 mm × 4.6 mm i.d., 5 μm) was used for the separation at ambient temperature, with 50mM ammonium dihydrogen phosphate (adjusting with phosphoric acid to pH 3.0) and acetonitrile as the mobile phase at the flow rate of 0.5 ml min(-1). VB(1), VB(3), VB(6), VC and VB(5) were extracted with a solution containing 0.05% phosphoric acid (v/v) and 0.3% sodium thiosulfate (w/v), and were then simultaneously analyzed by using the mobile phase of phosphate buffer-acetonitrile (95:5, v/v), while VB(2) and VB(9) were extracted with a solution containing 0.5% ammonium hydroxide solution (v/v), and were then simultaneously analyzed by using the mobile phase of phosphate buffer-acetonitrile (85:15, v/v). The detection wavelengths were 275 nm for VB(1), VB(3), VB(6), VC, 210 nm for VB(5), and 282 nm for VB(2) and VB(9). The method showed good system suitability, sensitivity, linearity, specificity, precision, stability and accuracy. All the seven water-soluble vitamins were well separated from other ingredients and degradation products. Method comparison indicated good concordance between the developed method and the USP method. The developed method was reliable and convenient for the rapid determination of VB(1), VB(3), VB(6), VC, VB(5), VB(2) and VB(9) in VMT.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Ammoniumhydroxid -Lösung, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Ammoniumhydroxid -Lösung, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
Natriumthiosulfat, ReagentPlus®, 99%
Sigma-Aldrich
Ammoniumphosphat, einbasig, ACS reagent, ≥98%
Sigma-Aldrich
Natriumthiosulfat Pentahydrat, ACS reagent, ≥99.5%
Sigma-Aldrich
Ammoniumphosphat, ACS reagent, ≥98%
Sigma-Aldrich
Natriumthiosulfat, purum p.a., anhydrous, ≥98.0% (RT)
Sigma-Aldrich
Ammoniumphosphat, einbasig, ReagentPlus®, ≥98.5%
Sigma-Aldrich
Ammoniumphosphat, einbasig, ≥99.99% trace metals basis
Sigma-Aldrich
Ammoniumphosphat, reagent grade, ≥98.0%
Sigma-Aldrich
Natriumthiosulfat Pentahydrat, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Natriumthiosulfat, ≥99.99% trace metals basis
Sigma-Aldrich
Ammoniumphosphat, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98% (alkalimetric)
Sigma-Aldrich
Ammoniumdihydrogenphosphat, 99.999% trace metals basis
Sigma-Aldrich
Ammoniumphosphat, ≥99.99% trace metals basis
Sigma-Aldrich
Ammoniumhydroxid -Lösung, BioUltra, ~1 M NH3 in H2O (T)
Supelco
(−)-Riboflavin, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Natriumthiosulfat Pentahydrat, 99.999% trace metals basis
Sigma-Aldrich
Ammoniumphosphat, einbasig, BioUltra, ≥99.5% (T)
Sigma-Aldrich
Natriumthiosulfat Pentahydrat, BioXtra, ≥99.5%
Sigma-Aldrich
Ammoniumphosphat, einbasig, suitable for plant cell culture
Sigma-Aldrich
Ammoniumphosphat, BioUltra, ≥99.0% (T)
Supelco
Ammoniumphosphat, einbasig, analytical standard, for nitrogen determination according to Kjeldahl method, ≥99.5%