Millipore Express® SHF, Opticap® XL Kapsel

inlet connection diam. 9/16 in., Opticap® XL 150, pore size 0.2 μm, cartridge nominal length 3.8 in. (9.7 cm)

Synonym(e):

Opticap XL 150 Millipore Express SHF Gamma Compatible 0.2 μm 3/4 in. TC-9/16 in. HB

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
23151806

Materialien

polyethersulfone
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap
polysulfone
silicone seal

Qualitätsniveau

Einhaltung gesetzlicher Vorschriften

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

Sterilität

non-sterile

Kompatibilität mit Sterilisationsverfahren

gamma compatible

Produktlinie

Opticap® XL 150

Leistungsmerkmale

gamma compatible
hydrophilic

Hersteller/Markenname

Millipore Express®

Parameter

1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure

Methode(n)

sterile filtration: suitable

Länge

9.7 cm (3.8 in.)

Breite

2.2 in.

Nennlänge Kartusche

3.8 in. (9.7 cm)

Durchmesser

5.6 cm (2.2 in.)

Filtrationsfläche

220 cm2

Durchm. Einlassanschluss

9/16 in.

Breite Einlass bis Auslass

9.7 cm (3.8 in.)

Durchm. Auslassanschluss

9/16 in.

Verunreinigungen

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

Matrix

Millipore Express® SHF

Porengröße

0.2 μm pore size

Blasenpunkt

≥4000 mbar (58 psig), air with water at 23 °C

Fitting

1/4 in. drain/vent hose barb (with double O-ring seal)
inlet hose barb
outlet hose barb
(14 mm (9/16 in.) Hose Barb Inlet and Outlet)

Allgemeine Beschreibung

Device Configuration: Filtereinheit

Verpackung

Double Easy-Open bag

Sonstige Hinweise

Diese Produkte werden in einem Werk hergestellt, das den GMP-Richtlinien der FDA entspricht.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Angaben zur Herstellung

Sterilization Method
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Hinweis zur Analyse

Bacterial Retention
Quantitative Rückhaltung von Brevundimonas diminuta bei einer Mindestbeaufschlagung von 1 x 10⁷ KBE/cm² unter Anwendung der ASTM® F838-Methode.
Erfüllt die Anforderungen des USP-Tests auf oxidierbare Substanzen nach Durchspülen mit ≥1 l Wasser
TOC/Conductivity
After sterilization and a controlled water flush of 2.0 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.

Rechtliche Hinweise

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Haftungsausschluss

EMD Millipore Corporation bestätigt, dass dieses Produkt der europäischen Druckgeräterichtlinie 97/23/EG vom 29. Mai 1997 entspricht. Dieses Produkt wurde unter Artikel 3 § 3 der Druckgeräterichtlinie klassifiziert. Das Produkt wurde in Übereinstimmung mit anerkannten technischen Methoden entwickelt und hergestellt, um einen sicheren Betrieb zu gewährleisten. In Konformität mit Artikel 3 § 3 dieser Druckgeräterichtlinie besitzt dieses Produkt kein CE-Zeichen.

Not finding the right product?  

Try our Produkt-Auswahlhilfe.


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Verwandter Inhalt

Learn how prefilters and bioburden control can improve the efficiency of downstream purification by removing particulates and protecting unit operations.

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.