Direkt zum Inhalt
Merck
Alle Fotos(2)

Key Documents

HTS042M

Sigma-Aldrich

ChemiScreen BLT1 Membrane Preparation

Human BLT1 GPCR membrane preparation for Radioligand binding Assays & GTPgammaS binding.

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
41106514
eCl@ss:
32161000
NACRES:
NA.84

Biologische Quelle

human

Qualitätsniveau

Rekombinant

expressed in Chem-1 cells

Verpackung

pkg of 1 mL

Hersteller/Markenname

ChemiScreen
Chemicon®

Konzentration

0.5 mg/mL (per vial)

Methode(n)

ligand binding assay: suitable (GTPγS)
radioligand binding assay (RLBA): suitable

NCBI-Hinterlegungsnummer

UniProt-Hinterlegungsnummer

Versandbedingung

dry ice

Allgemeine Beschreibung

BLT1 receptor is a Gi-coupled GPCR that binds primarily to the eicosanoid leukotriene B4. Macrophages, leukocytes and eosinophils express BLT1, and in vivo, BLT1 appears to mediate leukocyte migration and inflammation (reviewed in Brink et al., 2003). Chemicon′s BLT1 membrane preparations are crude membrane preparations made from our proprietary stable recombinant cell lines to ensure high-level of GPCR surface expression; thus, they are ideal HTS tools for screening of antagonists of BLT1 interactions with Leukotriene B4. The membrane preparations exhibit a Kd of 1.3 nM for [3H]-Leukotriene B4. With 5.0 μg/well BLT1 Membrane Prep and 1 nM [3H]-Leukotriene B4, a signal-to-background ratio of approximately 3-fold is obtained.
Human BLT1

Anwendung

Human BLT1 GPCR membrane preparation for Radioligand binding Assays & GTPgammaS binding.
Radioligand binding assay, and GTPgammaS binding.

Biochem./physiol. Wirkung

GPCR Class: A
Protein Target: BLT1
Target Sub-Family: Leukotriene

Qualität

SPECIFICATIONS:
Signal:background and specific binding values obtained in a competition binding assay with varying amounts of Motilin Receptor membrane prep:
5 µg/well10 µg/well
Signal:Background 75 65
Specific Binding (cpm) 46348 54457


1 unit = 5µg membrane preparation
Bmax: 5.6 pmol/mg
Kd: 0.43 nM

Spezifikationen

Inucbation Conditions
RECOMMENDED ASSAY CONDITIONS: Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, a GF/C 96-well filter plate is coated with 0.33% polyethyleneimine for 30 min, then washed with 50mM HEPES, pH 7.4, 0.5% BSA. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer. The plate is dried and counted.

Binding buffer: 50 mM Hepes, pH 7.4, 5 mM MgCl2, 1 mM CaCl2, 0.2% BSA, filtered and stored at 4°C

Radioligand: [3H] Luekotriene (Perkin Elmer# NEX378)

Wash Buffer: 50 mM Hepes, pH 7.4, 500mM NaCl , 0.1% BSA, filtered and stored at 4°C.

One package contains enough membranes for at least 200 assays (units), where a unit is the amount of membrane that will yield greater than 2.5-fold signal:background or 500 cpm with 3H-labeled Leukotriene B4 at 1 nM

Physikalische Form

Liquid in packaging buffer: 50 mM Tris pH 7.4, 10% glycerol and 1% BSA no preservatives.

Packaging method: Membranes protein were adjusted to the indicated concentration in packaging buffer, rapidly frozen, and stored at -80°C.

Lagerung und Haltbarkeit

Maintain frozen at -70°C for up to 2 years. Do not freeze and thaw.

Rechtliche Hinweise

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany

Haftungsausschluss

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Lagerklassenschlüssel

12 - Non Combustible Liquids

WGK

WGK 2


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.