Direkt zum Inhalt
Merck

HNPMAG-35K

Millipore

MILLIPLEX® Human Neuropeptide Magnetic Bead Panel - Neuroscience Multiplex Assay

The analytes available for this multiplex kit are: α-MSH, β-Endorphin, Neurotensin, Oxytocin, Substance P.

Synonym(e):

Human Neuroscience Protein Multiplex Assay, Luminex® Human Neuroscience Panel, Millipore Human Neuroscience Immunoassay

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
12161503
eCl@ss:
32161000
NACRES:
NA.84

Qualitätsniveau

Speziesreaktivität

human

Hersteller/Markenname

Milliplex®

assay range

accuracy: 98-118%
(Spike Recovery)

sensitivity: 11-479 pg/mL
(MinDC+2SD)

standard curve range: 27-20,000 pg/mL
(α-MSH)

standard curve range: 41-30,000 pg/mL
(Neurotensin)

standard curve range: 55-40,000 pg/mL
(Oxytocin)

standard curve range: 69-50,000 pg/mL
(β-Endorphine)

standard curve range: 7-5,000 pg/mL
(Substance P)

Methode(n)

multiplexing: suitable

Nachweisverfahren

fluorometric (Luminex xMAP)

Versandbedingung

wet ice

Allgemeine Beschreibung

The central nervous system is a complex environment consisting of billions of neurons and glial support cells. These neurons use chemical signals to communicate information. Neuropeptides are neuronal signaling molecules secreted by the central and peripheral nervous systems, influencing a broad spectrum of biological functions including the regulation of metabolism, reproduction, immunity, and behavior. Understanding the role of neuropeptides in the pathogenesis of devastating neuronal diseases and behavioral disorders is fundamental. While it is understood that accurate measurement of neuropeptides is important, conventional methods, including RIAs and ELISAs, are not able to simultaneously measure multiple neuropeptides with small sample volume. MILLIPLEX® Human Neuropeptide Bead Panel is a 5-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma, cerebrospinal fluid (CSF), tissue/cell lysate, and culture supernatant samples: α-Melanocyte Stimulating Hormone (α-MSH), β-Endorphin, Neurotensin, Oxytocin, and Substance P.

The MILLIPLEX® Human Neuropeptide Bead Panel is to be used for the simultaneous quantification of the following 5 analytes in any combination: α-MSH, β-Endorphin, Neurotensin, Oxytocin, and Substance P. This kit may be used for the analysis of all or any combination of the above analytes in tissue/cell lysate, culture supernatant samples, and cerebrospinal fluid (CSF). Serum or plasma samples may also be used and will need to be extracted. An important note about this conversion panel is that the samples may be extracted using either the acetonitrile precipitation technique or the Waters 96-well HLB extraction plate. Please refer to the protocol for more information on both methods. The necessary components to perform the extractions are not included with the kit.

Panel Type: Neuroscience

Spezifität

There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes within a panel.

Anwendung

  • Analytes: α-MSH, β-Endorphin, Neurotensin, Oxytocin, Substance P
  • Note that this is a competitive assay.
  • Recommended Sample type: serum, plasma, tissue culture supernatant, or CSF
  • Recommended Sample dilution: extracted serum or plasma or neat CSF or culture supernatant
  • Assay Run Time: Overnight
  • Research Category: Neuroscience

Leistungsmerkmale und Vorteile

Design your multiplex kit by choosing available analytes within this panel.

Verpackung

Everything you need in a single kit.

Komponenten

Human Neuropeptide Standard, 1 vial, lyophilized

Human Neuropeptide Quality Control 1, 1 vial, lyophilized

Human Neuropeptide Quality Control 2, 1 vial, lyophilized

Assay Buffer, 2 bottles, 30 mL ea.

Wash Buffer, 10X (0.05% Proclin), 2 bottles, 30 mL ea

Human Neuropeptide Primary Antibodies, 1 bottle, 3.5 mL

Human Neuropeptide Detection Antibodies, 1 bottle, 5.5 mL

Human Neuropeptide Matrix Solution, 1 bottle, 1.5 mL

Human Neuropeptide Antibody-Immobilized Magnetic Beads, 20X, 200 uL ea

Streptavidin-Phycoerythrin, 1 bottle, 5.5 mL

Mixing Bottle, 1 bottle

Sample Plate, 96 well format, 1 plate with 2 Foil Plate Sealers

Lagerung und Haltbarkeit

Recommended storage for kit components is 2 - 8°C.

Sonstige Hinweise

Sensitivity: Refer to kit protocol for sensitivities of individual biomarkers.

Rechtliche Hinweise

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany

Haftungsausschluss

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Piktogramme

Skull and crossbonesEnvironment

Signalwort

Danger

Gefahreneinstufungen

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1

Lagerklassenschlüssel

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 3


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Emmanuel Bäckryd et al.
Pain medicine (Malden, Mass.), 15(1), 111-119 (2013-10-15)
Pain medicine still lacks mechanism-specific biomarkers to guide diagnosis and treatment, and defective top-down modulation is an important factor in the pathophysiology of chronic pain conditions. Using modern analytical tools and advanced multivariate statistical analysis, the aim of this study
Olga V Roschina et al.
Journal of clinical medicine, 10(23) (2021-12-11)
The neuropeptides β-endorphin and oxytocin are released into the bloodstream as hormones from the pituitary gland but also have an important function as neuroregulators in the forebrain. The blood levels of both polypeptides have been shown to reflect depressive symptoms.
Ann M Manzardo et al.
American journal of medical genetics. Part A, 170(9), 2328-2333 (2016-08-16)
Prader-Willi syndrome (PWS) is a rare genetic neurodevelopmental disorder associated with maladaptive social behavior, hyperphagia and morbid obesity. Orexin A is a hypothalamic neuropeptide important as a homeostatic regulator of feeding behavior and in energy metabolism through actions in the
Immediate effects of spinal manipulation on nitric oxide, substance P and pain perception.
Molina-Ortega, F; Lomas-Vega, R; Hita-Contreras, F; Plaza Manzano, G; Achalandabaso et al.
Manual therapy null
Marco Barbariga et al.
Investigative ophthalmology & visual science, 59(3), 1305-1312 (2018-04-07)
The purpose of this study was to investigate the role of substance P (SP) in patients affected with corneal neovascularization (CNV) and in three different Tac1-knockout (KO) murine models of CNV. SP levels in tears were measured with a multiplex

Verwandter Inhalt

Multiplex detection of Alzheimer's biomarkers with MILLIPLEX® Human Amyloid Beta and Tau Magnetic Bead Panel aids research.

Neuroscience multiplex assays measure biomarkers to understand neurodegenerative diseases, disorders, and neuropeptide signaling.

Finden Sie Immunassays zur Bestimmung von Zytokinen mit Relevanz auf dem Gebiet der Neuroimmunologie und bei Neuroinflammation sowie von Biomarkern für neurodegenerative Erkrankungen.

Find immunoassays to explore neuroimmunology and neuroinflammation cytokines and neurodegenerative disease biomarkers.

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.