HND3MAG-39K
MILLIPLEX® Human Neurological Disorders Magnetic Bead Panel 3 - Neuroscience Multiplex Assay
The analytes available for this multiplex kit are: AGT, Contactin-1, Fetuin A, Kallikrein-6, OPN, sSOD1, sSOD2
About This Item
Empfohlene Produkte
Qualitätsniveau
Speziesreaktivität
human
Hersteller/Markenname
Milliplex®
assay range
accuracy: 69-92%
(Cerebrospinal fluid (CSF))
accuracy: 71-107%
(Serum)
standard curve range: 0.03-25 ng/mL
(SOD2)
standard curve range: 0.04-30 ng/mL
(Kallikrein-6)
standard curve range: 0.04-30 ng/mL
(SOD1)
standard curve range: 0.08-60 ng/mL
(Contactin-1)
standard curve range: 0.14-100 ng/mL
(Osteopontin (OPN))
standard curve range: 1.37-1,000 ng/mL
(AGT)
standard curve range: 4.12-3,000 ng/mL
(Fetuin A)
Methode(n)
multiplexing: suitable
Nachweisverfahren
fluorometric (Luminex xMAP)
Versandbedingung
wet ice
Allgemeine Beschreibung
NOTE: For serum and plasma samples Fetuin A requires a higher (1:4000) dilution and therefore must be assayed alone as a singleplex. For serum or plasma samples all analytes, except Fetuin A, require a 1:50 dilution and may be assayed together as a multiplex.
The MILLIPLEX® Human Neurological Disorders Bead Panel 3 (Cat. No. HND3MAG-39K) is to be used for the simultaneous quantification of the following 7 analytes in any combination in CSF, serum or plasma samples: Angiotensinogen (AGT), Contactin-1, Fetuin A, Kallikrein-6, Osteopontin (OPN), Soluble Superoxide Dismutase 1 (SOD1), Soluble Superoxide Dismutase 2 (SOD2).
NOTE: For serum and plasma samples Fetuin A requires a higher (1:4000) dilution and therefore must be assayed alone as a singleplex. For serum or plasma samples all analytes, except Fetuin A, require a 1:50 dilution and may be assayed together as a multiplex.
Panel Type: Neuroscience
Spezifität
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
Anwendung
- Analytes: Angiotensinogen (AGT), Contactin-1, Fetuin A, Kallikrein-6, Osteopontin (OPN), Soluble Superoxide Dismutase 1 (SOD1), Soluble Superoxide Dismutase 2 (SOD2)
- Recommended Sample type: CSF, serum, and plasma
- Recommended Sample dilution: 1:100 for CSF, 1:50 for serum and plasma for all analytes except Fetuin A, 1:4000 for serum and plasma for Fetuin A
- NOTE: Fetuin A cannot be assayed along with other analytes in serum/plasma samples. Fetuin A should be diluted 1:4000 in the kit Assay Buffer and analyzed as a singleplex for serum and plasma samples
- Assay Run Time: One day or Overnight
- Research Category: Neuroscience
Leistungsmerkmale und Vorteile
Verpackung
Lagerung und Haltbarkeit
Sonstige Hinweise
Rechtliche Hinweise
Haftungsausschluss
Signalwort
Danger
Gefahreneinstufungen
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
Zielorgane
Respiratory Tract
Lagerklassenschlüssel
10 - Combustible liquids
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Verwandter Inhalt
Multiplex detection of Alzheimer's biomarkers with MILLIPLEX® Human Amyloid Beta and Tau Magnetic Bead Panel aids research.
Neuroscience multiplex assays measure biomarkers to understand neurodegenerative diseases, disorders, and neuropeptide signaling.
Finden Sie Immunassays zur Bestimmung von Zytokinen mit Relevanz auf dem Gebiet der Neuroimmunologie und bei Neuroinflammation sowie von Biomarkern für neurodegenerative Erkrankungen.
Find immunoassays to explore neuroimmunology and neuroinflammation cytokines and neurodegenerative disease biomarkers.
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.