1.07179
n-Pentan
for spectroscopy Uvasol®
Synonym(e):
Pentan
About This Item
Dampfdichte
2.48 (vs air)
Qualitätsniveau
Assay
≥99.5% (GC)
Form
liquid
Selbstzündungstemp.
500 °F
Wirksamkeit
>2000 mg/kg LD50, oral (Rat)
Expl.-Gr.
~8.3 %
Methode(n)
UV/Vis spectroscopy: suitable
Verunreinigungen
≤0.0002 meq/g Acidity
≤0.0002 meq/g Alkalinity
≤0.005% Water
Abdampfrückstand
≤0.0002%
Farbe
APHA: ≤10
Durchlässigkeit
200 nm, ≥50%
210 nm, ≥70%
215 nm, ≥85%
225 nm, ≥95%
240 nm, ≥98%
Brechungsindex
n20/D 1.358 (lit.)
bp
35-36 °C (lit.)
mp (Schmelzpunkt)
−130 °C (lit.)
Übergangstemp.
flash point -48 °C (refers to pure substance)
Löslichkeit
0.4 g/L
Dichte
0.626 g/mL at 25 °C (lit.)
UV-Absorption
λ: 200 nm Amax: ≤0.30
λ: 210 nm Amax: ≤0.16
λ: 215 nm Amax: ≤0.07
λ: 225 nm Amax: ≤0.02
λ: 240 nm Amax: ≤0.01
Lagertemp.
2-30°C
SMILES String
CCCCC
InChI
1S/C5H12/c1-3-5-4-2/h3-5H2,1-2H3
InChIKey
OFBQJSOFQDEBGM-UHFFFAOYSA-N
Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich
Verwandte Kategorien
Allgemeine Beschreibung
Anwendung
- Quantitative determination of nitrous oxide in human blood by HS-GC-MS: forensic application of two fatal poisoning cases.: This study leverages n-Pentane in headspace gas chromatography-mass spectrometry (HS-GC-MS) for the forensic analysis of nitrous oxide in human blood. Highlighting its importance in forensic science, the research demonstrates n-Pentane′s utility in providing accurate and reliable measurements essential for legal and medical evaluations (Li Z et al., 2024).
- A photochromic trinuclear dysprosium(iii) single-molecule magnet with two distinct relaxation processes.: This article describes the use of n-Pentane in the synthesis of a dysprosium-based single-molecule magnet, showcasing its role in developing materials with unique magnetic properties for potential applications in quantum computing and data storage (Rogacz K et al., 2024).
- Reduction of Thorium Tris(amido)arene Complexes: Reversible Double and Single C-C Couplings.: This research employs n-Pentane in the study of thorium complexes, providing insights into reversible carbon-carbon coupling reactions. The findings contribute to the understanding of actinide chemistry and its application in recycling and waste reduction strategies (Deng C et al., 2024).
- Tuning Reactivities of tert-Butyllithium by the Addition of Stoichiometric Amounts of Tetrahydrofuran.: The study utilizes n-Pentane to adjust the reactivity of tert-butyllithium, illustrating its significant role in enhancing the control over chemical reactions. This advancement is pivotal for the synthesis of complex molecules in pharmaceuticals and materials science (Kleinheider J et al., 2024).
- Steps to achieve carvone-rich spearmint (Mentha spicata L.) essential oil: a case study on the use of different distillation methods.: In this research, n-Pentane is examined for its efficacy in extracting high-quality essential oils from spearmint, demonstrating its versatility in botanical extractions and its impact on the quality and characteristics of the essential oils obtained (Moradi-Sadr J et al., 2023).
Hinweis zur Analyse
Abdampfrückstand: ≤ 0,0002 %
Wasser: ≤ 0,005 %
Farbe: ≤ 10 Hazen
Acidität: ≤ 0,0002 meq/g
Alkalität: ≤ 0,0002 meq/g
Fluoreszenz (als Chinin bei 254 nm): ≤ 1,0 ppb
Fluoreszenz (als Quinin bei 365 nm): ≤ 1,0 ppb
Durchlässigkeit (bei 200 nm): ≥ 50 %
Durchlässigkeit (bei 210 nm): ≥ 70 %
Durchlässigkeit (bei 215 nm): ≥ 85 %
Durchlässigkeit (bei 225 nm): ≥ 95 %
Durchlässigkeit (ab 240 nm): ≥ 98 %
Absorption (bei 200 nm): ≤ 0,30
Absorption (bei 210 nm): ≤ 0,16
Absorption (bei 215 nm): ≤ 0,07
Absorption (bei 225 nm): ≤ 0,02
Absorption (ab 240 nm): ≤ 0,01
Erfüllt die Anforderungen einer „Spektroskopie zur spezifischen Verwendung“ gemäß Reag. Ph Eur
Sonstige Hinweise
Rechtliche Hinweise
Signalwort
Danger
H-Sätze
Gefahreneinstufungen
Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 2 - STOT SE 3
Zielorgane
Respiratory system
Zusätzliche Gefahrenhinweise
Lagerklassenschlüssel
3 - Flammable liquids
WGK
WGK 2
Flammpunkt (°F)
-40.0 °F
Flammpunkt (°C)
-40 °C
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.