240508

Sigma-Aldrich

1,1,2-Trichlor-1,2,2-trifluorethan

anhydrous, 99.8%

Synonym(e):

1,1,2-Trichlortrifluorethan, Genetron® 113

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
ClCF2CCl2F
CAS-Nummer:
Molekulargewicht:
187.38
Beilstein:
1740335
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12352101
PubChem Substanz-ID:
NACRES:
NA.21

Qualität

anhydrous

Dampfdichte

2.39 (vs air)

Dampfdruck

18.81 psi ( 55 °C)
5.5 psi ( 20 °C)
5.69 psi ( 20 °C)

Assay

99.8%

Form

liquid

Selbstzündungstemp.

1256 °F

Verunreinigungen

<0.002% water
<0.005% water (100 mL pkg)

Abdampfrückstand

<0.0005%

Brechungsindex

n20/D 1.358 (lit.)

bp

47-48 °C (lit.)

mp (Schmelzpunkt)

−35 °C (lit.)

Dichte

1.57 g/mL at 25 °C (lit.)

SMILES String

FC(F)(Cl)C(F)(Cl)Cl

InChI

1S/C2Cl3F3/c3-1(4,6)2(5,7)8

InChIKey

AJDIZQLSFPQPEY-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Verpackung

Packaged under nitrogen in Sure/Seal bottles

Rechtliche Hinweise

Genetron is a registered trademark of Honeywell International Inc.
Sure/Seal is a trademark of Sigma-Aldrich Co. LLC

Piktogramme

Exclamation markEnvironment

Signalwort

Warning

Gefahreneinstufungen

Aquatic Chronic 2 - Eye Irrit. 2 - Ozone 1

Lagerklassenschlüssel

10 - Combustible liquids

WGK

WGK 2

Flammpunkt (°F)

383.0 °F

Flammpunkt (°C)

195 °C

Persönliche Schutzausrüstung

Eyeshields, Gloves, multi-purpose combination respirator cartridge (US)


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

H K Xiao et al.
American Industrial Hygiene Association journal, 51(7), 402-404 (1990-07-01)
Results obtained using Fourier transform infrared spectrophotometry (FTIR) for the analysis of samples of carbon disulfide (CS2) eluates containing trichloroethylene (TCE) and Freon from charcoal air sampling tubes were evaluated by comparison with results obtained when using gas chromatography (GC).
J A Richt et al.
Medical microbiology and immunology, 182(5), 271-280 (1993-11-01)
Treatment of homogenates from Borna disease virus (BDV)-infected brain tissue or cell cultures with Freon-113 yielded infectious particles with a buoyant density of 1.16-1.22 g/ml. Positive- and negative-stranded BDV-specific RNA species as well as three virus-specific proteins, known to be
Y Michael et al.
International journal of pharmaceutics, 221(1-2), 165-174 (2001-06-09)
The nature of the drug-drug aggregation phenomena between salmeterol xinafoate and fluticasone propionate used in a metered-dose inhaler system has been examined. Interactions between the drugs in the solvents 1,1,2-trichlorotrifloroethane (CFC-113) and 1,1,1,2-tetrafluoroethane (HFA-134a) have been characterised using a focused
Mette Christophersen et al.
Journal of contaminant hydrology, 81(1-4), 1-33 (2005-08-17)
An emplaced hydrocarbon source field experiment was conducted in the relatively homogeneous sandy geology of the vadose zone at Airbase Vaerløse, Denmark. The source (10.2 l of NAPL) consisted of 13 hydrocarbons (n-, iso- and cyclo-alkanes and aromates) and CFC-113
M Neghab et al.
International archives of occupational and environmental health, 70(3), 187-194 (1997-01-01)
The objectives of this study were threefold. First, to examine the hepatic effects of occupational exposure to 1,1,2-trichloro-1,2,2-trifluoroethane (FC 113) using conventional and newer tests (serum bile acids) of hepatobiliary function. Second, to assess the effects of altered work practices

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.