Skip to Content
Merck

Skip To

EZHPYYT

Human PYY ELISA Kit

measures and quantifies total PYY levels in 20 μL serum or plasma

Synonym(s):

PYY ELISA Kit

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
96 wells

Estimated to ship onMay 28, 2026fromAreál Kühne+Nagel spol. s r.o.

CZK 22,100.00
1 kit

Estimated to ship onMay 28, 2026fromAreál Kühne+Nagel spol. s r.o.

CZK 147,600.00

About This Item

UNSPSC Code:
12161503
eCl@ss:
32161000
NACRES:
NA.32
Input:
sample type plasma (K2 EDTA)
sample type serum
Species reactivity:
human
Storage temp.:
2-8°C
Shipped in:
wet ice

CZK 22,100.00


Estimated to ship onMay 28, 2026Details


Request a Bulk Order
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Product Name

Human PYY (Total) ELISA, This Human PYY (Total) ELISA is used to measure & quantify PYY (Total) levels in Metabolism & Endocrine & Neuroscience research.

Quality Segment

species reactivity

human

packaging

kit of 1 × 96 wells

parameter

20 μL sample volume (4hr assay)

technique(s)

ELISA: suitable

input

sample type plasma (K2 EDTA)
sample type serum

NCBI accession no.

UniProt accession no.

application(s)

research use

assay range

accuracy: 83.3-88.9%
(Serum), accuracy: 95.9-102.5%
(Plasma), linearity: 94-99%
(plasma), linearity: 97-105%
(serum), sensitivity: 1.4 pg/mL, standard curve range: 10-2,000 pg/mL, inter-assay cv: 3.7-16.5%
intra-assay cv: 0.9-5.8%
(Plasma), inter-assay cv: 6.1-6.9%
intra-assay cv: 1.5-2.7%
(Serum)

detection method

colorimetric (450nm/590nm)

shipped in

wet ice

storage temp.

2-8°C

General description

Peptide YY (PYY) is a hormone released by the lower GI tract with circulating levels increasing after meals in direct proportion to the caloric content. It is one of the major physiological signals to reduce appetite and food intake. Other functions of PYY are the inhibition of gastric acid secretion, GI motility and pancreatic enzyme output.

Application

3 hour assay using 20 µL sample size ~ Room Temperature
Research Category
Metabolism
Research Sub Category
Obesity

Metabolic Disorders
Used to detect/quantify: PYY (Total)

Biochem/physiol Actions

Human PYY 3-36 100%~Human PYY 1-36 104%~Human [Leu31,Pro34] PYY 138%~Human [Pro34] PYY 158%~Porcine, Canine, Rat, or Mouse PYY Not Detectable

Disclaimer

For research use only. Not for use in diagnostic procedures.

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
EZGRAEZHGIPEZGRT
species reactivity

human

species reactivity

human

species reactivity

human

species reactivity

human

assay range

accuracy: 83.3-88.9%
(Serum), linearity: 94-99%
(plasma), sensitivity: 1.4 pg/mL, inter-assay cv: 3.7-16.5%
intra-assay cv: 0.9-5.8%
(Plasma), accuracy: 95.9-102.5%
(Plasma), standard curve range: 10-2,000 pg/mL, inter-assay cv: 6.1-6.9%
intra-assay cv: 1.5-2.7%
(Serum), linearity: 97-105%
(serum)

assay range

-

assay range

accuracy: 86.7%, linearity: 99.9%, sensitivity: 8.2 pg/mL, standard curve range: 8.2-2000 pg/mL

assay range

accuracy: 101-107%
(Serum: Des-octanoyl Ghrelin), accuracy: 88-91%
(Serum: Active Ghrelin), linearity: 95-117%
(plasma), linearity: 95.7-104.7%
(serum), sensitivity: 156 pg/mL
(20 µL Sample Size), inter-assay cv: 5.2-7.7%
intra-assay cv: 1.1-1.9%
(Plasma), inter-assay cv: 6.2-7.8%
intra-assay cv: 0.9-1.3%
(Serum)

input

sample type plasma (K2 EDTA)
sample type serum

input

sample type plasma (K2 EDTA)
sample type serum

input

sample type cell culture supernatant
sample type serum
sample type plasma (K2 EDTA)

input

sample type plasma (K2 EDTA)
sample type serum

Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

200

detection method

colorimetric (450nm/590nm)

detection method

colorimetric (450nm/590nm)

detection method

colorimetric (450nm/590nm)

detection method

colorimetric (450nm/590nm)

technique(s)

ELISA: suitable

technique(s)

ELISA: suitable

technique(s)

ELISA: suitable

technique(s)

ELISA: suitable


signalword

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Met. Corr. 1 - Repr. 1B - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3

target_organs

Respiratory system

Storage Class

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

wgk

WGK 3



Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

Reviews

No rating value

Active Filters