1.19637
LiChrospher® 100 RP-18 endcapped (5 µm) HPLC Columns
HPLC sorbent
Synonym(s):
TM=["LiChrospher"] C18 sorbent for HPLC
About This Item
Recommended Products
product name
LiChrospher® 100 RP-18 endcapped (5 µm),
material
stainless steel column
Agency
suitable for USP L1
product line
LiChrospher®
feature
endcapped
packaging
1 ea of
extent of labeling
21.6% Carbon loading
parameter
60 °C max. temp.
technique(s)
HPLC: suitable
mass spectrometry (MS): suitable (Low - Medium)
surface area
350 m2/g
matrix
fully porous particle
matrix active group
C18 bonding phase
particle size
5 μm
pore size
100 Å pore size
operating pH range
2-7.5
bulk density
200‑400 kg/m3
separation technique
reversed phase
storage temp.
no temp limit
Related Categories
General description
Application
- Simultaneous quantification of delta-9-THC, THC-acid A, CBN and CBD in seized drugs using HPLC-DAD: The robustness of the LiChrospher® 60 RP-select B column is highlighted in forensic science, where it is used to accurately identify and quantify cannabinoids, demonstrating its critical role in legal and forensic analyses (Ambach et al., 2014).
- RP-HPLC separation and characterization of unknown impurities of a novel HIV-protease inhibitor Darunavir by ESI-MS and 2D NMR spectroscopy: The LiChrospher® 60 RP-select B column′s exceptional selectivity and performance are utilized to identify novel impurities in Darunavir, highlighting its application in developing more effective HIV treatments (Nageswara Rao et al., 2013).
- Quantification of pralidoxime (2-PAM) in urine by ion pair chromatography-diode array detection: Demonstrating versatility, this column was used to detect therapeutic agents in clinical settings, supporting treatment regimes for poisonings where rapid and accurate drug monitoring is essential (John et al., 2012).
Analysis Note
Pressure: ≤ 50 bar
Theoretical Plates (N/m) (Toluene): ≥ 60000
stability testing (performance): passes test
Particle Size (d10): 4.8 - 5.5 µm
Particle Size (d50): 6.5 - 7.5 µm
Particle Size (d90): 9.0 - 10.5 µm
Legal Information
Storage Class Code
11 - Combustible Solids
WGK
nwg
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service