Key Documents

21228

Supelco

GC Stationary Phase

phase OV-101, bottle of 20 g

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

UNSPSC Code:
23151817

agency

meets requirements for USP G1

packaging

bottle of 20 g

parameter

0-350 °C temp. range

technique(s)

gas chromatography (GC): suitable

matrix active group

OV-101 phase

solubility

chloroform: soluble

column type

packed GC

General description

GC methods are divided into two classes depending on the nature of stationary phases; gas-solid chromatography (GSC) and gas-liquid chromatography (GLC). GSC has solid adsorptive material and solute particles are removed from mobile phase by electrostatic forces. GLC has a thin layer of liquid coated or bonded on the surface of an inert particle or on the walls of the column where solute particles are retained in the liquid phase based on their partition coefficients. The primary necessity of a stationary phase is to provide sample separation sustaining phase integrity over a reasonable period of time. It should be stable for the chemical and thermal changes. Selectivity, peak symmetry, analysis time, degree of separation, peak tailing are few parameters to consider for choosing a stationary phase. OV-101 is a modified silicone polymer which has good temperature stability. It is suitable as liquid phases in chromatograph.
Synthesized specifically to be purer, of narrow molecular weight range, and without trace catalysts or impurities for use as a GC stationary phase.

Application

OV-101 is a suitable stationary phase for monitoring the urinary excretion in man for pentachlorophenol (PCP) and PCP conjugated to glucuronic acid, using gas chromatography with electron capture detection (GC/ECD).

Storage Class

10 - Combustible liquids

wgk_germany

WGK 1

flash_point_f

214.0 °F - closed cup

flash_point_c

101.1 °C - closed cup

ppe

Eyeshields, Gloves


Vyberte jednu z posledních verzí:

Osvědčení o analýze (COA)

Lot/Batch Number

Je nám líto, ale pro tento produkt momentálně nemáme COA k dispozici online.

Potřebujete-li pomoc, obraťte se na Zákaznická podpora

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

S Uhl et al.
Archives of toxicology, 58(3), 182-186 (1986-02-01)
Pentachlorophenol (PCP) was given orally to three volunteers at single doses of 3.9, 4.5, 9, and 18.8 mg. Daily urinary excretion of PCP and PCP conjugated to glucuronic acid was monitored using gas chromatography with electron capture detection (GC/ECD). Based
Harold M. McNair, James M. Miller
Basic Gas Chromatography (2011)
David B. Troy, Paul Beringer
Remington: The Science and Practice of Pharmacy, 605-605 (2006)
James P. Lodge, Jr.
Methods of Air Sampling and Analysis, 98-98 (1988)

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..