Přejít k obsahu
Merck

TRUE6

TrueGel3D Hydrogel Kits

SLO-DEXTRAN, allow cell recovery, PEG non cell-degradable crosslinker

Synonyma:

3D Hydrogel Kit, TrueGel3D Kit

Přihlásit pro zobrazení organizačních a smluvních cen.

Vybrat velikost

Změnit zobrazení

O této položce

NACRES:
NA.71
UNSPSC Code:
12352207
Storage temp.:
−70°C
Shipped in:
dry ice
Technický servis
Potřebujete pomoc? Náš tým zkušených odborníků je vám k dispozici.
Dovolte nám, abychom vám pomohli


shipped in

dry ice

storage temp.

−70°C

General description

The gel is formed by stable thioether bonds between thiol groups on PEG non cell-degradable crosslinker and thio-reactive groups on SLO-DEXTRAN. The polymer, SLO-DEXTRAN is functionalized with thiol-reactive groups which react with crosslinker at slower rate than maleimides in FAST-DEXTRAN. SLO-DEXTRAN does not have sites for cell attachment, but it can be customized to conjugate RGD peptide using TrueGel3D RGD peptide (TRUERGD-1EA) prior to the crosslinking step.

TrueGel3D enzymatic cell recovery solution (TRUEENZ-500UL) is used to dissolve dextran polymers for easy recovery of chemically fixed or live cells for post-culture analyses including RT-PCR, western blots and other molecular biological studies.

Application

TRUE6-1KT is used to generate hydrogels of different stiffness (0.15 to 5 KPa shear modulus) to mimic natural tissue stiffness and to investigate the effect of mechanical stimulus on cell physiology and behavior. It is also used to culture non-proliferating cells and proliferating spheroids that do not attach to hydrogel for survival, but rather use their own extracellular matrix.

Features and Benefits

  • Slow gelling (takes 8 minutes to 25 minutes, depends on gel stiffness)
  • Flexibility in modulating gel stiffness
  • Does not allow cell migration
  • Allow cell recovery and post-culture analyses
  • Cell inert hydrogel (if not customized with RGD peptide)

Other Notes

TRUE6-1KT contains SLO-DEXTRAN solution in phosphate buffer and lyophilized PEG non cell-degradable crosslinker with reconstitution buffer and water.

Disclaimer

Avoid prolong exposure of PEG non cell-degradable crosslinker to air.


Still not finding the right product?

Explore all of our products under TrueGel3D Hydrogel Kits


pictograms

Corrosion

signalword

Warning

Hazard Classifications

Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2

wgk

WGK 3

Skladovací třída

10 - Combustible liquids



Vyberte jednu z posledních verzí:

Osvědčení o analýze (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumenty section.

Potřebujete-li pomoc, obraťte se na Zákaznická podpora

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů