Přejít k obsahu
Merck
Všechny fotografie(1)

Hlavní dokumenty

08729

Supelco

Silicon Standard for ICP

TraceCERT®, 1 g/L Si in nitric acid (nominal concentration)

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

UNSPSC Code:
41116107
NACRES:
NA.24

grade

certified reference material
TraceCERT®

Quality Level

product line

TraceCERT®

concentration

1 g/L Si in nitric acid (nominal concentration)

technique(s)

ICP: suitable

application(s)

industrial qc
pharmaceutical

format

single component solution

General description

This certified reference material (CRM) is produced in accordance with ISO 17034 and characterized in accordance with ISO/IEC 17025. This CRM is traceable to SI unit kg and measured against primary material from a National Metrology Institute (NMI), e.g. NIST.

Please visit ISO certificates and Site Quality Self-Assessments to access the current certificates of accreditation.

Download your certificate at https://www.sigma-aldrich.com to view certified values, including uncertainty, date of expiry, and detailed information about trace impurities.

Application

Silicon ICP standard can be used as a calibration standard in the determination of silicon concentration in organosilica materials by inductively coupled plasma optical emission spectroscopy (ICP-OES).

Analysis Note

1 g/L Si in 2% HNO3 (contains HF traces), prepared with high purity Si, HNO3, HF, and water

Other Notes

For a complete product listing of our TraceCERT™ range of CRMs for ICP and AAS, technical information and example certificates, please visit our ICP & AAS standards website
For a complete product listing of our TraceCERT® range of CRMs for ICP and AAS, technical information and example certificates, please visit our ICP & AAS standards website

Legal Information

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

pictograms

Corrosion

signalword

Warning

Hazard Classifications

Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2

Storage Class

8B - Non-combustible corrosive hazardous materials

wgk_germany

nwg

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter


Vyberte jednu z posledních verzí:

Osvědčení o analýze (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumenty section.

Potřebujete-li pomoc, obraťte se na Zákaznická podpora

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Zákazníci si také prohlíželi

Influence of monomer connectivity, network flexibility, and hydrophobicity on the hydrothermal stability of organosilicas
Dral A, et al.
Langmuir, 33, 5527-5536 (2017)

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.