25420-U
Columna para GC capilar SP®-5
L × I.D. 30 m × 0.53 mm, df 1.00 μm
Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización
About This Item
Productos recomendados
material
fused silica
Quality Level
agency
meets requirements for USP G27 and G36
parameter
-60-300 °C temperature (isothermal)
-60-320 °C temperature (programmed)
Beta value
133
df
1.00 μm
technique(s)
gas chromatography (GC): suitable
L × I.D.
30 m × 0.53 mm
matrix active group
Bonded; poly(5% diphenyl/95% dimethyl siloxane) phase
column type
capillary non-polar
¿Está buscando productos similares? Visita Guía de comparación de productos
General description
Capillary GC column is also known as open tubular column. The carrier gas flows through the central aperture and is unrestricted throughout the length of the column.
Aplicación: Esta columna no polar de uso general proporciona principalmente un orden de elución por punto de ebullición con un ligero aumento en la selectividad, en especial para los compuestos aromáticos.
Código USP: Esta columna cumple los requisitos G27 y G36 de la USP .
Fase:
Código USP: Esta columna cumple los requisitos G27 y G36 de la USP .
Fase:
- Ligada
- Poli(difenil al 5 %/dimetil siloxano al 95 %)
- ≤0,32 mm D.I., <2 μm: de -60 °C a 320 °C (isotérmica o programada)
- ≤0,32 mm D.I., ≥2 μm: de -60 °C a 300 °C (isotérmica o programada)
- ≥0,53 mm D.I., <2 μm: de -60 °C a 300 °C (isotérmica ) o 320 °C (programada)
- ≥0,53 mm D.I., ≥2 μm: de -60 °C a 260 °C (isotérmica ) o 280 °C (programada)
Application
SPB®-5 Capillary GC Column may be used as stationary phase for determination of nivalenol and deoxynivalenol in cereals by electron-capture gas chromatography.
Other Notes
We offer a variety of chromatography accessories including analytical syringes
Legal Information
SPB is a registered trademark of Merck KGaA, Darmstadt, Germany
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Determination of nivalenol and deoxynivalenol in cereals by electron-capture gas chromatography.
Journal - Association of Official Analytical Chemists, 69 (5), 889-893 (1985)
Journal of chromatography. A, 985(1-2), 211-220 (2003-02-13)
The sterol composition of extra virgin olive oil is very characteristic and, thus, has become a helpful tool to detect adulterations with other vegetable oils. Special attention has been addressed to the separate determination of the free and esterified sterol
Talanta, 106, 14-19 (2013-04-20)
4-Methylsterols and 4,4-dimethylsterols of 47 samples of subcutaneous fat from Iberian pigs reared on two different fattening systems, "Extensive" and "Intensive", have been analyzed by GC-MS and GC-FID. The lipids were extracted by melting the subcutaneous fat in a microwave
Development of a passive sampler to measure personal exposure to gaseous PAHs in community settings.
Environmental science & technology, 40(19), 6051-6057 (2006-10-21)
A sensitive, simple, and cost-effective passive sampling methodology was developed to quantify personal exposure to gaseous polycyclic aromatic hydrocarbons (PAHs). A Fan-Lioy passive PAH sampler (FL-PPS) is constructed from 320 sections of 1-cm long SPB-5 GC columns (0.75-mm i.d. and
Veterinarni medicina, 37(8), 471-478 (1992-08-01)
Occurrence of individual polychlorinated biphenyl (PCB) congeners in the environment, foodstuffs and other biological materials was assessed. Analysis of specific PCB congeners (28, 52, 101, 138, 153, 180), occurring in animal raw materials and foodstuffs most frequently, has been implemented.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico