HNABTMAG-68K
MILLIPLEX® Human Amyloid Beta and Tau Magnetic Bead Panel - Multiplex Assay
allows quantitative multiplex detection of multiple analytes simultaneously
Synonym(s):
Human Neuroscience Protein Multiplex Assay, Luminex® Human Neuroscience Panel, Millipore Human Neuroscience Immunoassay
About This Item
Recommended Products
Quality Level
species reactivity
human
manufacturer/tradename
Milliplex®
assay range
accuracy: 109%
(Spike recovery for Aβ1-42)
accuracy: 91%
(Spike recovery for pTau181)
accuracy: 98%
(Spike recovery for tTau)
sensitivity: 1.5 pg/mL
(pTau181; MinDC+2SD)
sensitivity: 10.2 pg/mL
(A?1-40; MinDC+2SD)
sensitivity: 14.2 pg/mL
(tTau; MinDC+2SD)
sensitivity: 2.5 pg/mL
(A?1-42; MinDC+2SD)
standard curve range: 0.7-500 pg/mL
(pTau181)
standard curve range: 11-8000 pg/mL
(tTau)
standard curve range: 2-2000 pg/mL
(Aβ1-42)
standard curve range: 21-15000 pg/mL
(Aβ1-40)
inter-assay cv: <15%
intra-assay cv: <10%
technique(s)
multiplexing: suitable
detection method
fluorometric (Luminex xMAP)
shipped in
wet ice
General description
The MILLIPLEX® Human Amyloid Beta Tau Bead Panel is to be used for the simultaneous quantification of Aβ40, Aβ42, tTau, and pTau181. This kit may be used only for the analysis of cerebrospinal fluid (CSF). This is a configurable assay, and some or all analytes can be selected: tau (total), amyloid β40, amyloid β42 and tau (pThr181).
MILLIPLEX® portfolio offers the broadest selection of analytes across a wide range of disease states and species. Once the analytes of interest have been identified, you can rely on the quality that we build into each kit to produce results you can trust. In addition to the assay characteristics listed in the protocol, other performance criteria evaluated during the validation process include: cross-reactivity, dilution linearity, kit stability and sample behavior (e.g. detectability and stability). Each panel and kit meets stringent manufacturing criteria to ensure batch-to-batch reproducibility.
Each MILLIPLEX® panel and kit includes:
• Quality controls (QCs) provided to qualify assay performance
• Comparison of standard (calibrator) and QC lots to a reference lot to ensure lot-to-lot consistency
• Optimized serum matrix to mimic native analyte environment
• Detection antibody cocktails designed to yield consistent analyte profiles within panel
MILLIPLEX® Human Amyloid Beta Tau Bead Panel is part of the most versatile system available for cytokine research. From our single to multiplex biomarker solutions, we partner with you to design, develop, analytically validate, and build the most comprehensive library available for protein detection and quantitation.
Panel Type: Neuroscience
Specificity
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes within a panel.
Application
- Analytes: Tau (Total), Amyloid β40, Amyloid β42, Tau (pThr181)
- Recommended Sample type: cerebrospinal fluid (CSF)
- Recommended Sample dilution: 1:2 sample dilution is recommended for extracted CSF samples
- Assay Run Time: Overnight
- Research Category: Neuroscience Metabolism
- Research Subcategory: Metabolic Disorders Obesity Inflammation & Autoimmune Mechanisms
- Research Category Neuroscience Metabolism
- NOTE: This is a competitive assay
Features and Benefits
Packaging
Components
Human ABeta and Tau Quality Control 1, 1 vial, lyophilized
Human ABeta and Tau Quality Control 2, 1 vial, lyophilized
Bead Diluent, 1 bottle, 3.5mL
Set of one 96-Well Plate with 2 sealers
Assay Buffer, 1 bottle, 30 mL
Wash Buffer, 10X (0.05% Proclin), 2 bottles, 30 mL ea
Human ABeta and Tau Detection Antibodies, 1 bottle, 3.2 mL
Streptavidin-Phycoerythrin, 1 bottle, 3.2 mL
Mixing Bottle, 1 bottle
Storage and Stability
Legal Information
Disclaimer
Signal Word
Danger
Hazard Statements
Precautionary Statements
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Related Content
MILLIPLEX® multiplex immunoassays detect Alzheimer's biomarkers in neuroscience research using high sensitivity technology.
MILLIPLEX® multiplex immunoassays detect Alzheimer's biomarkers in neuroscience research using high sensitivity technology.
MILLIPLEX® multiplex immunoassays detect Alzheimer's biomarkers in neuroscience research using high sensitivity technology.
MILLIPLEX® multiplex immunoassays detect Alzheimer's biomarkers in neuroscience research using high sensitivity technology.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service