40156

Supelco

Pentachloronitrobenzene solution

certified reference material, 5000 μg/mL in methanol

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Numéro CAS:
Numéro MDL:
Code UNSPSC :
41116105

Qualité

certified reference material
TraceCERT®

Niveau de qualité

Agence

EPA 508,508A,8080,8081,8082,508.1

Gamme de produits

TraceCERT®

CofA (certificat d'analyse)

current certificate can be downloaded

Caractéristiques

standard type internal

Conditionnement

ampule of 1 mL

Concentration

5000 μg/mL in methanol

Technique(s)

HPLC: suitable
gas chromatography (GC): suitable

Application(s)

environmental

Format

single component solution

Température de stockage

2-8°C

Chaîne SMILES 

Clc1c(c(c(c(c1Cl)Cl)[N+](=O)[O-])Cl)Cl

InChI

1S/C6Cl5NO2/c7-1-2(8)4(10)6(12(13)14)5(11)3(1)9

Clé InChI

LKPLKUMXSAEKID-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Application

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Autres remarques

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Informations légales

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

Mention d'avertissement

Danger

Classification des risques

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Aquatic Chronic 2 - Flam. Liq. 2 - STOT SE 1

Organes cibles

Eyes,Central nervous system

Code de la classe de stockage

3 - Flammable liquids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

49.5 °F - closed cup - Solvent

Point d'éclair (°C)

9.7 °C - closed cup - Solvent


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

Si vous avez besoin d'assistance, veuillez contacter Service Clients

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

L Alborch et al.
Letters in applied microbiology, 50(3), 270-275 (2010-01-15)
To assess differences between two recommended selective culture media, Nash and Snyder medium (NS) and malachite green agar 2.5 (MGA 2.5), for the detection of Fusarium infection in conventional and transgenic maize kernels. In total, 10 800 kernels from commercial
Weiguo Zhang et al.
Rapid communications in mass spectrometry : RCM, 20(10), 1563-1568 (2006-04-22)
The effects of overlapping levels and concentration ratios of overlapping components, and of scan rates of the mass spectrometer, on the capability of the automated mass spectral deconvolution and identification system (AMDIS) in pesticide residue analysis were studied. To investigate
Wang Zhang et al.
Journal of hazardous materials, 198, 275-281 (2011-11-15)
Pentachloronitrobenzene (PCNB) has been identified as a potential persistent organic pollutant, and received concerns from many countries for regulation due to its impurities such as dioxins and furans. Considering the need for its disposal, the mechanochemical destruction approach was investigated
H Huang
Zhong yao cai = Zhongyaocai = Journal of Chinese medicinal materials, 24(4), 239-241 (2003-02-18)
Residues of organic chloride pesticide were separated and detected successfully with high performance capillary column and high sensitive electron capture detector, such as hexachloro-cyclohexane, dichloro-diphenyl-trichloroethane, pentachloronitrobenzene. The method can be used for the determination of residues of organic chloride pesticide
Hadi Farahani et al.
Analytica chimica acta, 626(2), 166-173 (2008-09-16)
A simple and efficient liquid-phase microextraction (LPME) in conjunction with gas chromatography-electron capture detector (GC-ECD) has been developed for extraction and determination of 11 organochlorine pesticides (OCPs) from water samples. In this technique a microdrop of 1-dodecanol containing pentachloronitrobenzene (internal

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique