28463-U

Supelco

Colonne capillaire pour la GC VOCOL®

L × I.D. 20 m × 0.18 mm, df 1.00 μm

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
77101502
eCl@ss :
32119290
Nomenclature NACRES :
SB.54

Matériaux

fused silica

Niveau de qualité

Agence

EPA TO-17,502.2,624,8015,8260,OLM04.2 VOA,524.2
NIOSH 1003
suitable for EPA 601

Paramètres

≤25-250 °C temperature (isothermal or programmed)

Valeur bêta

45

df

1.00 μm

Technique(s)

gas chromatography (GC): suitable (fast GC)

L × D.I.

20 m × 0.18 mm

Application(s)

environmental
food and beverages
forensics and toxicology
industrial hygiene

Type de colonne

capillary intermediate polar

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Application : Cette colonne de polarité intermédiaire, conçue pour l′analyse des composés organiques volatils (COV), permet une grande rétention et une bonne résolution de composés très volatils. Cette colonne peut être utilisée dans les ports d′injection directe ou couplée à des systèmes de purge et piégeage.
Code USP : Aucun
Phase :
  • greffée
  • Déposée
Limites de température :
  • ≤0,32 mm D.I., <2 μm : De sub-ambiante à 250 °C (isotherme ou programmée)
  • ≤0,32 mm D.I., ≥2 μm : De sub-ambiante à 230 °C (isotherme ou programmée)
  • ≥0,53 mm D.I., <2 μm : De sub-ambiante à 250 °C (isotherme ou programmée)
  • ≥0,53 mm D.I., ≥2 μm : De sub-ambiante à 230 °C (isotherme ou programmée)

Autres remarques

We offer a variety of chromatography accessories including analytical syringes

Informations légales

VOCOL is a registered trademark of Merck KGaA, Darmstadt, Germany

Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Zuleica A Camargo et al.
Logopedics, phoniatrics, vocology, 38(4), 157-166 (2013-07-06)
In this phonetic study, productions of the consonant in the stressed syllable position of the word arara as produced by 13 subjects with short and/or anterior lingual frenulum were compared before and after lingual frenectomy. The results from the measurement
Re: Bonilha HS, O'Shields M, Gerlach TT, Deliyski DD. Arytenoid adduction asymmetries in persons with and without voice disorders. Logoped Phoniatr Vocol. 2009 Aug 26:1-7. [E-pub ahead of print].
Gerhard Friedrich
Logopedics, phoniatrics, vocology, 35(3), 149-149 (2009-11-04)
Anne Rosing-Schow et al.
Logopedics, phoniatrics, vocology, 35(4), 166-168 (2010-10-12)
VoiceRelease is a progressively structured treatment system that aims to release the voice through muscle tension reduction by manual therapy, thereby facilitating healthy voice production. The VoiceRelease treatment should closely interact with functional voice training and should therefore be carried
Ben Barsties et al.
Logopedics, phoniatrics, vocology, 41(1), 27-32 (2014-08-05)
The aim of the study was to determine the impact of body height on speaking fundamental frequency (SF0) while controlling for as many as possible influencing factors such as habits, biophysical conditions, medication, diseases, and others. Fifty-eight females were analyzed
Nanna Palle et al.
Logopedics, phoniatrics, vocology, 39(1), 19-29 (2012-11-30)
The purpose was to investigate an intervention model for treating preschool children with phonological processes. Six children, three girls and three boys, between 4y 1m and 5y 7m, with similar developmental phonological disorder (PD) received an individually adjusted intervention including

Contenu apparenté

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

Chromatograms

suitable for GCsuitable for GC

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique