Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

CCW4721

Millipore

Coliforms Chromogenic Agar Plates

Solid, selective, and differential culture medium for the detection and enumeration of total coliform and E. coli in water samples by the membrane-filtration technique acc. to ISO, suitable for microbiology

Synonyme(s) :

CCA

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41171606
Nomenclature NACRES :
NA.74

Agence

ISO 9308-1:2014

Niveau de qualité

Forme

solid

Durée de conservation

5 mo. (Expiry date on the label)

Caractéristiques

ready-to-use

Composition

agar, 13.00 g/L
5-bromo-4-chloro-3-indoxyl-β-D-glucuronic acid, 0.10 g/L
6-chloro-3-indoxyl-β-D-galactopyranoside, 0.10 g/L
di-sodium hydrogen phosphate, 2.70 g/L
enzymatic digest of casein, 1.00 g/L
IPTG, 0.10 g/L
sodium chloride, 5.00 g/L
Sodium dihydrogen phosphate dihydrate, 2.20 g/L
sodium pyruvate, 1.00 g/L
sorbitol, 1.00 g/L
Tergitol 7, 0.15 g/L
tryptophan, 1.00 g/L
yeast extract, 2.00 g/L

Conditionnement

box of 30 plates

Conditions de stockage

(Store dry and tightly closed)

Paramètres

9 mL filling volume

Diam. de la plaque/du plateau

55 mm

Couleur

pale yellow

pH

6.8±0.2 (25 °C)

Application(s)

food and beverages
microbiology

Température de stockage

2-25°C

Adéquation

Escherichia coli
coliforms

Description générale

Coliforms Chromogenic Agar Plates are ready-to-use plates to detect and enumerate total coliform and E. coli in water samples. The combined action of peptone, pyruvate, and sorbitol allows rapid colony growth in this phosphate-buffered medium, which also permits simple recovery of sublethal thermally injured coliforms. Sodium chloride provides the correct osmotic environment necessary for growth. The selectivity is attained partially by the Tergitol 7, which inhibits the growth of Gram-positive and some Gram-negative bacteria without affecting the coliform bacteria. The culture medium is formulated without antibiotics for water samples with low bacterial background flora. The colonial differentiation is due to the chromogenic mixture, composed of two enzyme substrates: 6-chloro-3-indoxyl-ß-D-galacto-pyranoside (Salmon-GAL) and 5-bromo-4-chloro-3-indoxyl-ß-D-glucuronide (X-Glucuronide). ß-D-galactosidase in coliforms cleaves the first substrate, giving a salmon-red color to the coliform colonies. The ß-D-glucuronidase enzyme, characteristic of E. coli, cleaves the second chromogenic substrate, giving blue color to their colonies.E. coli has two enzymes that cleave both chromogenic substances giving dark blue to violet colonies. Total coliforms are the sum of E. coli colonies and the salmon-red colonies. The IPTG enhances the metabolism of chromogens. Other Gram-negative bacteria produce colorless colonies. However, some Gram-negative bacteria possessing glucuronidase activity (not galactosidase) produce light blue to turquoise colonies.E. coli colonies are confirmed by including a small amount of tryptophane in the medium and coating the blue-violet colonies with a drop of Kovacs Reagent. The color change of the reagent to cherry-red in a few seconds confirms the production of indole and thereby, the presence of E. coli. When the Chromogenic Agar for Coliform is used with the membrane filter method, the color and growth of the colonies can be modified by the characteristics of the membrane filter. It is advisable to perform validation of the membrane filter type used.

Application

Coliforms Chromogenic Agar Plates are suitable for the detection and enumeration of total coliform and E. coli in water samples by the membrane-filtration technique.

Composants

1 box containing: 6 plastic bags with 5 plates of 55 mm/bag

Autres remarques

If the membrane filtration method is used, it must be considered that the nature and characteristics of the filter membrane used also influences the size and color of the colonies grown on this culture medium.

Informations légales

TERGITOL is a trademark of The Dow Chemical Company ("Dow") or an affiliated company of Dow

Code de la classe de stockage

13 - Non Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 1

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique