06185
Acide benzoique
Standard for quantitative NMR, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
About This Item
Produits recommandés
Qualité
Standard for quantitative NMR
certified reference material
TraceCERT®
Niveau de qualité
Densité de vapeur
4.21 (vs air)
Pression de vapeur
10 mmHg ( 132 °C)
Description
qNMR Standard for organic solvents (8.2-7.4 ppm)
Forme
crystalline
Température d'inflammation spontanée
1061 °F
Durée de conservation
limited shelf life, expiry date on the label
Fabricant/nom de marque
Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Technique(s)
gas chromatography (GC): suitable
qNMR: suitable
Point d'ébullition
249 °C (lit.)
Pf
121-125 °C (lit.)
Application(s)
cleaning products
cosmetics
flavors and fragrances
food and beverages
personal care
pharmaceutical
Format
neat
Chaîne SMILES
OC(=O)c1ccccc1
InChI
1S/C7H6O2/c8-7(9)6-4-2-1-3-5-6/h1-5H,(H,8,9)
Clé InChI
WPYMKLBDIGXBTP-UHFFFAOYSA-N
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Description générale
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma-aldrich.com.
Check out our entire range of quantitative NMR standards (qNMR standards)
Autres remarques
suitable NMR solvents: MeOD, DMSO-d6
Produits recommandés
Informations légales
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Eye Dam. 1 - Skin Irrit. 2 - STOT RE 1 Inhalation
Organes cibles
Lungs
Code de la classe de stockage
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Classe de danger pour l'eau (WGK)
WGK 1
Point d'éclair (°F)
Not applicable
Point d'éclair (°C)
Not applicable
Faites votre choix parmi les versions les plus récentes :
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Articles
The signal ratio of two different protons can be measured with tremendous precision, which enables the generation of certified reference materials for use as qNMR standards.
NMR shift charts assist in identifying impurities in deuterated solvents, aiding accurate chemical analysis.
NMR shift charts assist in identifying impurities in deuterated solvents, aiding accurate chemical analysis.
NMR shift charts assist in identifying impurities in deuterated solvents, aiding accurate chemical analysis.
Contenu apparenté
ChemisTwin automates NMR result interpretation, saving time with structure confirmation and quantitative NMR measurements using electronic Reference Materials.
ChemisTwin automates NMR result interpretation, saving time with structure confirmation and quantitative NMR measurements using electronic Reference Materials.
ChemisTwin automates NMR result interpretation, saving time with structure confirmation and quantitative NMR measurements using electronic Reference Materials.
ChemisTwin automatise l'interprétation des résultats RMN, ce qui permet de gagner du temps lors de la confirmation des structures et des mesures RMN quantitatives à l'aide de matériaux de référence électroniques.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique