1.50426
Chromolith® CapRod RP-18 endcapped (monolithic) HPLC Columns
L × I.D. 50 mm x 0.1 mm trap Capillary Column
Synonyme(s) :
Chromolith® CapRod RP-18 endcapped 50-0.1 trap capillary column
About This Item
Produits recommandés
product name
Chromolith® CapRod RP-18 endcapped Capillary Columns, L × I.D. 50 mm x 0.1 mm trap capillary column
Matériaux
PEEK column
Niveau de qualité
Agence
suitable for USP L1
Gamme de produits
Chromolith®
Caractéristiques
endcapped
Conditionnement
1 ea of
Ampleur du marquage
18% Carbon loading
Paramètres
200 bar pressure
Technique(s)
HPLC: suitable
LC/MS: suitable (Capillary LC)
mass spectrometry (MS): suitable (High)
Colonne, L × D.I.
5 cm × 0.1 mm
Matrice
monolithic silica
Groupe de la matrice active
C18 bonding phase
Dimension de pores
13 nm mesoporosity
2 μm macroporosity
operating pH range
2-7.5
Technique de séparation
reversed phase
Température de stockage
no temp limit
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Description générale
Compared to particulate capillary columns, Chromolith® CapRod capillaries demonstrate better performance with optimal resolution (narrow peak widths), increased productivity (higher sample throughput), and extended column lifetime. Furthermore, column length is less limited than with any other type of column. The capillaries can even be slightly bent to fit any LC configuration or instrument.
Chromolith® CapRod columns are designed to work with various nano or capillary-LC systems. This provides the highest efficiency and performance when coupled to mass spectrometers, both on-line (ESI, nanospray) and off-line (MALDI).
Why choose Chromolith® CapRod capillary columns?
—Higher flow rates than particle-packed capillary columns
—Columns at low pressure
—Long column lifetime
—Robust and easy handling
—Flow rates from 0.1–200 μL/min ensure ideal compatibility with LC/MS systems, with both ESI and APCI interfaces
Chromolith® CapRod RP-18 endcapped monolithic Trapping Column is a capillary trap that is used to concentrate samples before transfering them to the analytical Chromolith® CapRod column. The typical flow rate for this 50-0.1 trap capillary column ranges from 1 μL/min to 10 μL/min.
Learn more:
Brochure: Race through your Separations on Any System. Chromolith® Monolithic Silica HPLC Columns
Informations légales
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique