G004220
GC Analysis of PCBs in Transformer Oil on a 5% Phenyl Column after SPE using Supelclean™ Sulfoxide
suitable for GC, application for SPE
About This Item
tecniche
gas chromatography (GC): suitable
solid phase extraction (SPE): suitable
Parametri analitici
SPE tube/cartridge: Supelclean Sulfoxide SPE Tube, Glass 6 g/20 mL (55252-U)
sample preparation: SPE (Solid Phase Extraction)
column: 5% phenyl polysiloxane (Supelco equivalent, SLB-5ms, 28471-U)
sample addition: transformer oil spiked with PCBs
detector: QMS (For full method details, please see reference (1))
extraction process: Sample Pre-treatment: paraffin oil was spiked with a Kanechlor PCB mix at the total levels of 3.7 ppm (mg/kg) and diluted with hexane (1:1 v/v). (Commercial insulation oil (Japan Industrial Standard JIS C2320-1999, insulating oil, Class 1-2/4).)
condition: 20 mL acetone; 40 mL of hexane
sample addition: 0.4 mL diluted oil sample
elution: 12 mL hexane (elutes oil interferences); 25 mL hexane (elutes PCBs)
eluate post-treatment: concentrate under nitrogen
Compatibilità
application for SPE
applicazioni
environmental
Applicazioni
Commercial insulation oil (Japan Industrial Standard JIS C2320-1999, insulating oil, Class 1-2/4, paraffin oil) was spiked with a Kanechlor PCB mix at the total levels of 3.7 ppm (mg/kg) and diluted with hexane (1:1 v/v).
Note legali
Colonna analitica
Colonnina o piastra per SPE
Scegli una delle versioni più recenti:
Certificati d'analisi (COA)
Ci dispiace, ma al momento non ci sono COA disponibili online per questo prodotto.
Se ti serve aiuto, non esitare a contattarci Servizio Clienti
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.