Passa al contenuto
Merck
Tutte le immagini(2)

Documenti fondamentali

GE28-9505-16

HiScreen Phenyl High Performance

Cytiva 28-9505-16

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
13111000
NACRES:
NA.56
Prezzi e disponibilità al momento non sono disponibili

ligand

phenyl

Stato

prepacked column

Crosslinking

cross-linked

Confezionamento

pkg of 4.7 mL

Produttore/marchio commerciale

Cytiva 28-9505-16

Condizioni di stoccaggio

(20% Ethanol)

Parametri

44 psi

tecniche

liquid chromatography (LC): suitable

Dimensioni del letto

7.7 mm × 100 mm

Volume del letto

4.7 mL

Diam. int. colonna

7.7 mm

Matrice

6% cross-linked agarose

Gruppo funzionale matrice

Phenyl functional group

Dimensione particelle

24-44 μm

Dimens. media delle particelle

34 μm

cleaning

2-14

Intervallo di esercizio

3-13

Compatibilità

suitable for bioprocess medium (BioProcess medium.)
suitable for bioprocess medium

Tecnica di separazione

hydrophobic interaction (HIC)

Descrizione generale

HiScreen Phenyl HP columns are prepacked with Phenyl Sepharose High Performance hydrophobic interaction chromatography (HIC) media. The columns are an excellent choice for method optimization and parameter screening.

Applicazioni

The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up. If necessary, two columns can easily be connected in series to give a bed height of 20 cm. Media prepacked in HiScreen HIC columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.

Caratteristiche e vantaggi

  • Butyl Sepharose High Performance is an aliphatic HIC medium, designed for intermediate and polishing step purification steps when high resolution has priority.
  • Prepacked, ready-to-use columns for convenient process development optimization.
  • 10 cm bed height of HiScreen columns is designed to allow method optimization and parameter screening.
  • Easily connected in series to achieve 20 cm bed height.
  • Small bed volume gives fast results and minimal sample/buffer consumption.
  • Reproducible results, scalable to BioProcess columns packed with the same media using the same linear fluid velocity.

Stoccaggio e stabilità

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol or 0.01 M NaOH)
Store at 4 to 30 °C (20% Ethanol)

Risultati analitici

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Note legali

HiScreen is a trademark of Cytiva
Sepharose is a trademark of Cytiva

Prodotti correlati

N° Catalogo
Descrizione
Determinazione del prezzo

Pittogrammi

Flame

Avvertenze

Warning

Indicazioni di pericolo

Codice della classe di stoccaggio

3 - Flammable liquids


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documenti section.

Se ti serve aiuto, non esitare a contattarci Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.