Passa al contenuto
Merck
Tutte le immagini(1)

Documenti

GE17-1273-01

SOURCE 30S

Cytiva 17-1273-01, pack of 50 mL

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
47101511
NACRES:
NA.56

ligand

sulfonate group

Descrizione

Ion Exchanger Type (value)

Confezionamento

pack of 50 mL

Produttore/marchio commerciale

Cytiva 17-1273-01

Matrice

polystyrene/divinylbenzene

Dimensione particelle

30 μm

cleaning in place

1-14

working range

2-13

Compatibilità

suitable for bioprocess medium

Categorie correlate

Descrizione generale

SOURCE 30S is a polymeric, strong cation exchanger designed for intermediate purification and large-scale polishing.

Applicazioni

SOURCE 30S is a synthetic high performance, preparative, chromatography medium, based on a 30 μm monosized, rigid polystyrene/divinyl benzene polymer matrix It is modified with sulphonate (S) strong cation exchange groups. SOURCE media have excellent physical and chemical characteristics, allowing high flow rates and consistent performance at both laboratory and process scales.

SOURCE 30S is suitable for intermediate purification steps in industrial processes when large volumes of partially purified material need to be processed. A high degree of purification can be obtained with high productivity.

Through the combination of high quality assurance standards and a patented manufacturing process, particle structure is consistent both bead-to-bead and batch-to batch. As member of the BioProcess media range, SOURCE 30S meets industrial demands with security of supply and comprehensive technical and regulatory support.

Caratteristiche e vantaggi

  • Mono-sized 30 μm rigid beads gives Low back pressure and high flow rates allowing for high productivity
  • Strong cation exchanger designed for high resolution polishing purification of Proteins, peptides and oligonucleotides
  • High chemical stability allowing for wide range of working conditions with good resistance to cleaning conditions at high pH

Stoccaggio e stabilità

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol + 0.2 M Sodium Acetate)

Risultati analitici

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Note legali

SOURCE is a trademark of Cytiva

Pittogrammi

Flame

Avvertenze

Warning

Indicazioni di pericolo

Codice della classe di stoccaggio

3 - Flammable liquids


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Articoli

This page shows Hydrophobic Interaction Chromatography (HIC) in a purification strategy.

Protocolli

In this section the practical aspect of Reverse Phased Chromatography ( RPC) is discussed including media and column selection and eluent selection and preparation.

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.