Passa al contenuto
Merck
Tutte le immagini(3)

Documenti fondamentali

P1088

Sigma-Aldrich

Potassio ftalato monobasico

BioXtra, ≥99.95%

Sinonimo/i:

Acido ftalico, KHP, Potassio biftalato, Potassio idrogeno ftalato

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

100 G
CHF 94.10
500 G
CHF 324.00

CHF 94.10


Spedizione prevista il02 giugno 2025


Richiedi un ordine bulk

Scegli un formato

Cambia visualizzazione
100 G
CHF 94.10
500 G
CHF 324.00

About This Item

Formula condensata:
HOOCC6H4COOK
Numero CAS:
Peso molecolare:
204.22
Beilstein:
3637128
Numero CE:
Numero MDL:
Codice UNSPSC:
12161700
ID PubChem:
NACRES:
NA.25

CHF 94.10


Spedizione prevista il02 giugno 2025


Richiedi un ordine bulk

Nome Commerciale

BioXtra

Livello qualitativo

Saggio

≥99.95%

Stato

powder or crystals

Impurezze

<0.005% Insoluble matter
<0.005% Phosphorus (P)

pH

4

Punto di fusione

295-300 °C (dec.) (lit.)

Anioni in tracce

chloride (Cl-): <0.003%
sulfur compounds (as SO42-): ≤0.002%

Cationi in tracce

Al: <0.0005%
Ca: <0.005%
Cu: <0.0005%
Fe: <0.0005%
Mg: <0.0005%
NH4+: <0.05%
Na: <0.005%
Pb: <0.001%
Zn: <0.0005%

Stringa SMILE

[K+].OC(=O)c1ccccc1C([O-])=O

InChI

1S/C8H6O4.K/c9-7(10)5-3-1-2-4-6(5)8(11)12;/h1-4H,(H,9,10)(H,11,12);/q;+1/p-1
IWZKICVEHNUQTL-UHFFFAOYSA-M

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Descrizione generale

Potassium hydrogen phthalate (KHP) is a semi-organic salt that is a member of the alkali acid phthalate series. KHP crystals are useful in devices because of their electro-optical properties. It usually acts as a model compound due to its well-developed surface pattern on the (010) face that can be easily observed by optical microscopy.

Applicazioni

Potassium hydrogen phthalate has been used as a substrate to assess the permeation from the extracellular (EC) to the periplasmic (PP) side through DcaP. It has also been used as one of the polyurethane materials for the characterization of polyester triol (OH).

Caratteristiche e vantaggi

  • Long-term stability
  • Exhibits dielectric properties

Codice della classe di stoccaggio

11 - Combustible Solids

Classe di pericolosità dell'acqua (WGK)

WGK 1

Punto d’infiammabilità (°F)

387.1 °F - Pensky-Martens closed cup

Punto d’infiammabilità (°C)

197.3 °C - Pensky-Martens closed cup

Dispositivi di protezione individuale

Eyeshields, Gloves, type N95 (US)


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Slide 1 of 3

1 of 3

Meghan O'Connor et al.
Water research, 156, 23-33 (2019-03-25)
The organic matter present in wastewater effluents (EfOM), is likely to have different properties than the organic matter present in the receiving water. The properties of EfOM will affect the fate of contaminants of emerging concern because EfOM is a
Marta Guembe-García et al.
Polymers, 12(6) (2020-06-04)
We anchored a colourimetric probe, comprising a complex containing copper (Cu(II)) and a dye, to a polymer matrix obtaining film-shaped chemosensors with induced selectivity toward glycine. This sensory material is exploited in the selectivity detection of glycine in complex mixtures
Maria Cristina Fossi et al.
Marine pollution bulletin, 64(11), 2374-2379 (2012-09-12)
Baleen whales are potentially exposed to micro-litter ingestion as a result of their filter-feeding activity. However, the impacts of microplastics on baleen whales are largely unknown. In this case study of the Mediterranean fin whale (Balaenoptera physalus), we explore the
Juanjuan Feng et al.
Journal of chromatography. A, 1268, 16-21 (2012-11-07)
Because of the occurrence of ion exchange between high-ionic-strength solution and anions of polymeric ionic liquids (PILs), PILs based solid-phase microextraction (SPME) fibers were rarely used in direct immersion mode to high-salt-added samples. In this work, a novel double-confined PIL
Hanne Frederiksen et al.
Environmental science & technology, 47(2), 958-967 (2012-12-14)
Urinary phthalate excretion is used as marker of phthalate exposure in epidemiological studies. Here we examine the reliability of urinary phthalate levels in exposure classification by comparing the inter- and intrasubject variation of urinary phthalate metabolite levels. Thirty-three young healthy

Questions

1–4 of 4 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. Hi, Is the BioXtra grade equivalent to ACS grade and can we use this reagent for the standardization of NaOH solution as prescribed by the USP pharmacopeia (instead of the ACS grade) ? Thank you in advance.

    1 answer
    1. The BioXtra is not equivalent to the ACS grade. For the standardization of NaOH solutions, it is recommended to use Product 1024000083 which is a certified reference material (CRM) for the standardization of volumetric solutions in alkalimetric titrations, according to Ph. Eur.

      Helpful?

  4. I want to know the expiration date of KHP(P1088)

    1 answer
    1. This product is not assigned an expiration date or recommended retest date. Products with no expiration date or recommended retest date should be routinely inspected by customers to ensure they perform as expected. These products are also subject to a one year warranty from the date of shipment. For more information you may access the "Product Dating Information" document under "ADDITIONAL USEFUL DOCUMENTS ABOUT OUR PRODUCTS" at the bottom of the Quality Services page with this link: https://www.sigmaaldrich.com/life-science/quality-and-regulatory-management/quality-services.

      Helpful?

Reviews

No rating value

Active Filters

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.