The 10 kDa membrane suitable for this stirred cell is PLGC07610.
UFSC40001
Cella con agitatore Amicon® da 400mL
This Amicon stirred cell model provides high flow rates with solutions up to 10% macrosolute concentration. Capable of rapid concentration, or salt removal followed by concentration in the same unit.
Sinonimo/i:
Cella con agitatore Amicon
About This Item
Prodotti consigliati
Materiali
Nylon assembly (cap and tube fitting)
Nylon stand (retaining)
Tygon® tube (filtrate)
anodized aluminum stand (retaining)
polyacetal assembly (stirring)
polyethylene tube (pressure)
polysulfone assembly (stirring)
polysulfone holder (cylinder & membrane)
silicone O-ring
Livello qualitativo
Nome Commerciale
Amicon®
Produttore/marchio commerciale
Amicon®
Parametri
400 mL process volume
tecniche
protein clean-up: suitable (desalting)
protein purification: suitable (concentration)
Altezza
18.7 cm (7.4 in.)
Diam. filtro
76 mm
Superficie filtrante
41.8 cm2
Condizioni di spedizione
ambient
Applicazioni
Principio
Linkage
Note legali
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
I clienti hanno visto anche
Articoli
Amicon Stirred Cells concentrate and buffer-exchange macrosolutes efficiently with pressure-driven filtration.
-
Does this model have a 10 kDa membrane?
1 answer-
Helpful?
-
-
What is the minimum volume that can be concentrated using stirred cells? Additionally, what is the minimum volume that can be recovered from the stirred cell?
1 answer-
The stirred cells do not have a specified minimum concentrate volume, as this is typically dependent on the sample. According to the user guide, the minimum concentrate volume must be determined empirically by the user based on sample composition and stirring speed.
In theory, it is possible to concentrate to dryness; however, this is highly dependent on the sample and membrane used.
Additionally, the specification chart includes a hold-up volume, which indicates the volume of sample that is 'lost' to the device. For detailed hold-up volume information, please refer to page 10 of the user guide.
Helpful?
-
-
Could you please provide more information about the troubleshooting for a stirred cell that is not holding pressure and has poor concentrate recovery?
1 answer-
On September 7, 2021, the Eyre User Guide provided troubleshooting information on pages 8 and 9. It addressed the symptom of a stirred cell not holding pressure and poor concentrate recovery. The cause identified was a membrane that was not sealed, leading to sample bypass around the membrane. The corrective action recommended was to ensure that the O-ring is free of dirt or debris and undamaged.
Helpful?
-