LA1HCG6S2

Millipore

Millistak+® Lenticular Disc Filter

A1HC, cellulose, filtration area 1.8 m2, hydrophilic

Sinonimo/i:

Millistak+ Lenticular Disc Filters, A1HC media series, 16 in. diameter, 8-cell, silicone seal, 2/pack

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
23151806
eCl@ss:
32031690

Materiali

cellulose
filter aid (inorganic)
mixed cellulose esters (MCE)
polypropylene
silicone seal

Livello qualitativo

Descrizione

Post-TFF (Prostak) clarification fluids

Caratteristiche

hydrophilic

Produttore/marchio commerciale

Millistak+®

Parametri

0.03 bar max. differential pressure (0.5 psid) (Reverse)
0.2 bar max. inlet pressure (3 psi) at 123 °C
0.21 bar max. differential pressure (3 psid) at 123 °C (Forward)
1 bar max. inlet pressure (15 psi) at 80 °C
1.03 bar max. differential pressure (15 psid) at 80 °C (Forward)
2.07 bar max. differential pressure (30 psid) at 25 °C (Forward)
2.1 bar max. inlet pressure (30 psi) at 25 °C

Diametro

40.64 cm (16 in.)

Superficie filtrante

1.8 m2

Impurezze

<0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

non-volatile residue (NVR)

1.50-2.02 mg/m2 (gravimetric analysis test)

Carbonio Organico Totale (TOC) residuo

416-593 ppb (gravimetric analysis test)
565-1037 ppb

input

sample type liquid

Conducibilità

5-7 μmho per cm at 25 °C (product water)

Grado di filtrazione

A1HC

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Descrizione generale

Device Configuration: Stack Disk
Stack Design: 16 in. diameter, 8-cell

Applicazioni

Post-TFF (Prostak) clarification fluids

Specifiche

Filter Grade: A1HC

Nota sulla preparazione

Sanitization Protocol
May be hot water sanitized for 20 cycles using purified water @ 80 °C for 30 minutes
Sterilization Method
May be steam sterilized for 3 steam-in-place (SIP) cycles of 30 minutes @ 123 °C

Risultati analitici

Gravimetric Extractables: Post autoclave (1 cycle of 30 minutes at 123 °C) and pure water flush of 100 L/m2 (10 L/ft2) of media surface area
Product Water Conductivity at 25°C: after a pure water flush of 10 L/ft2 (100 L/m2) of media surface area per autoclaved (1 cycle of 30 minutes at 123 °C) 12" 16-stack device
The effluent of an autoclaved (1 cycle of 30 minutes @ 123 °C) stacked device is negative after a WFI flush of 10 liters per ft2 (100 L/m2) of media surface area
Total Organic Carbon (TOC) Residue: post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 10 liters per ft2 (100 L/m2) of media surface area

Note legali

MILLISTAK+ is a registered trademark of Merck KGaA, Darmstadt, Germany
Prostak is a trademark of Merck KGaA, Darmstadt, Germany

Pittogrammi

Health hazard

Avvertenze

Danger

Indicazioni di pericolo

Classi di pericolo

STOT RE 1 Inhalation

Organi bersaglio

Lungs

Codice della classe di stoccaggio

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Classe di pericolosità dell'acqua (WGK)

WGK 3


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.