KVVLA3STT1
Durapore® 0.1 µm, Opticap® XLT Capsule
Opticap® XLT 30, cartridge nominal length 30 in. (15 cm), filter diam. 5.7 in. (14.5 cm), pore size 0.1 μm
About This Item
Materiali
polypropylene device
polypropylene housing
polypropylene support
polypropylene vent cap
Livello qualitativo
Conformità normativa
meets FDA 21 CFR 177-182 (all component materials)
Sterilità
non-sterile
Compatibilità con la sterilizzazione
autoclavable compatible
Nome Commerciale
Opticap® XLT 30
Caratteristiche
hydrophilic
Produttore/marchio commerciale
Opticap®
Parametri
max. inlet temp. at 25 °C
≤60 mL/min air diffusion at 3.9 bar (56 psig) (in water)
1.7 bar max. differential pressure (25 psid) at 80 °C (Forward)
2.8 bar max. inlet pressure (40 psi) at 60 °C
3.5 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
tecniche
sterile filtration: suitable
Lunghezza
34.3 in.
Larghezza
6.0 in.
Lunghezza nominale della cartuccia
30 in. (15 cm)
Dimensioni del dispositivo
30 in.
Diam. filtro
5.7 in. (14.5 cm)
Superficie filtrante del filtro
2.1 m2
Ampiezza ingresso/ uscita
34.3 in. (87.1 cm)
Impurezze
≤0.5 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Matrice
Durapore®
Dimensione pori
0.1 μm pore size
Punto di bolla
≥4830 mbar (70 psig), air with water at 23 °C
Raccordi
1/4 in. drain/vent connection (with double O-ring Seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)
Cerchi prodotti simili? Visita Guida al confronto tra prodotti
Descrizione generale
Cartridge Type: Liquid
Caratteristiche e vantaggi
Nota sulla preparazione
Risultati analitici
Altre note
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Note legali
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Active Filters
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.