Passa al contenuto
Merck
Tutte le immagini(2)

Documenti fondamentali

HTS040M

Sigma-Aldrich

ChemiSCREEN Membrane Preparation Recombinant Human NOP Opioid Receptor

Human NOP / ORL1 / OP4 GPCR membrane preparation for Radioligand binding Assays & GTPγS binding.

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
41106514
eCl@ss:
32161000
NACRES:
NA.84

Origine biologica

human

Livello qualitativo

Ricombinante

expressed in Chem-1 cells

Produttore/marchio commerciale

ChemiScreen
Chemicon®

tecniche

ligand binding assay: suitable (GTPγS)
radioligand binding assay (RLBA): suitable

N° accesso UniProt

Condizioni di spedizione

dry ice

Descrizione generale

Full-length human OPRL1 cDNA encoding NOP
The NOP receptor (also known as ORL1) is related to the opioid receptor family of GPCRs but does not bind to classical opioids. An endogenous ligand for NOP has been characterized and termed orphanin FQ or nociceptin (OFQ/N), which in turn does not bind to other members of the opioid receptor family. NOP is expressed widely in the CNS, and binding of OFQ/N to NOP1 appears to function in nociception, locomotor activity, anxiety, reward, memory and tolerance to classical opioids (Mogil and Pasternak, 2001). Millipore′s NOP membrane preparations are crude membrane preparations made from our proprietary stable recombinant cell lines to ensure high-level of GPCR surface expression; thus, they are ideal HTS tools for screening of agonists and antagonists of NOP. The membrane preparations exhibit a Kd of 0.06 nM for [125II]-Nociceptin. With 0.1 nM [125I]-Nociceptin, 5μg/well NOP Membrane Prep typically yields greater than 10-fold signal-to-background ratio.

Applicazioni

Radioligand binding assay and GTPγS binding

Azioni biochim/fisiol

GPCR Class: A
Protein Target: NOP / ORL1 / OP4
Target Sub-Family: Opioid

Qualità

Table 1. Signal:background and specific binding values obtained in a competition binding assay with NOP Receptor membrane prep.
5 µg/well
Signal:Background 23.8
Specific Binding (cpm) 6656


SPECIFICATIONS: 1 unit = 5 µg
Bmax for [125I]-Nociceptin binding: 1.1 pmol/mg protein
Kd for [125I]-Nociceptin binding: ~0.06 nM

Specifiche

Inucbation Conditions
Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, an FC 96-well harvest plate (Millipore cat. # MAHF C1H) is coated with 0.33% polyethyleneimine for 30 min, then washed with 50 mM Tris-HCl, pH 7.4. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer. The plate is dried and counted.

Binding buffer: 50 mM Tris-HCl, pH 7.4 filtered and stored at 4°C

Radioligand: [125I]-Nociceptin. (Perkin Elmer#:NEX-324 )

Wash Buffer: 50 mM Hepes, pH 7.4, 500 mM NaCl , 0.1% BSA, filtered and stored at 4°C.

One package contains enough membranes for at least 200 assays (units), where a unit is the amount of membrane that will yield greater than 10-fold signal:background with 125I labeled Nociceptin

Stato fisico

Liquid in packaging buffer: 50 mM Tris pH 7.4, 10% glycerol and 1% BSA with no preservatives.
Packaging method: Membranes protein were adjusted to the indicated concentration in 1 ml packaging buffer, rapidly frozen, and stored at -80°C

Stoccaggio e stabilità

Maintain frozen at –70°C up to the expiration date indicated on the product label. Do not freeze and thaw.

Note legali

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany

Esclusione di responsabilità

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Codice della classe di stoccaggio

12 - Non Combustible Liquids

Classe di pericolosità dell'acqua (WGK)

WGK 2

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.