CCGL52TP1
Cartucce Durapore® a matrice caricata da 0,22 µm
cartridge nominal length 20 in. (50 cm), Code 5 (2-222; O-rings and spear)
Sinonimo/i:
Charged Durapore Cartridge 20 in. 0.22 μm Code 5
About This Item
Materiali
PVDF
polypropylene
polypropylene support
silicone seal
Livello qualitativo
Sterilità
non-sterile
Compatibilità con la sterilizzazione
autoclavable compatible
steam-in-place compatible
Nome Commerciale
Durapore®
Caratteristiche
hydrophilic
Produttore/marchio commerciale
Durapore®
Parametri
≤20 mL/min air diffusion at 2.1 bar (30 psig) and 23 °C (in water)
0.35 bar max. differential pressure (5 psid) at 135 °C (Forward)
0.35 bar max. inlet pressure (5 psi) at 135 °C (Forward)
1.7 bar max. differential pressure (25 psid) at 80 °C (Forward)
1.7 bar max. inlet pressure (25 psi) at 80 °C (Forward)
3.5 bar max. differential pressure (50 psid) at 25 °C (Reverse)
3.5 bar max. inlet pressure (50 psi) at 25 °C (Reverse)
45 L/min flow rate at 600 mbar (ΔP)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)
tecniche
sterile filtration: suitable
Lunghezza
20 in.
Lunghezza nominale della cartuccia
20 in. (50 cm)
Diametro
6.9 cm (2.7 in.)
Superficie filtrante
1.4 m2
Impurezze
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Estraibili (gravimetria)
≤40 mg/cartridge
Matrice
Charged Durapore®
Dimensione pori
0.22 μm
input
sample type liquid
Punto di bolla
≥2760 mbar (40 psig), air with water at 23 °C
Codice cartuccia
Code 5 (2-222; O-rings and spear)
Descrizione generale
Confezionamento
Altre note
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Nota sulla preparazione
10 SIP cycles of 30 min @ 135 °C
Risultati analitici
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Note legali
Not finding the right product?
Try our Motore di ricerca dei prodotti.
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.