Passa al contenuto
Merck

Vai a

APFF09050

Filtri a membrana in fibra di vetro, pori da 0,7 μm

Millipore, filter diam. 90 mm, hydrophilic, thickness 380 μm

Sinonimo/i:

Glass Fiber Filter without binder

Autenticati per visualizzare i prezzi organizzativi e contrattuali.

Scegli un formato

Cambia visualizzazione
A voi/SKUDisponibilitàPrezzo

Informazioni su questo articolo

UNSPSC Code:
40161507
NACRES:
NB.24
eCl@ss:
32031602
Pore size:
0.7 μm pore size, 90 % porosity
Material:
glass fiber membrane, plain filter, white filter
Feature:
hydrophilic
Diam.:
90 mm
Sterility:
non-sterile
Prezzi e disponibilità al momento non sono disponibili
Servizio Tecnico
Hai bisogno di aiuto? Il nostro team di scienziati qualificati è a tua disposizione.
Permettici di aiutarti


Quality Segment

material

glass fiber membrane, plain filter, white filter

description

0.7 µm pore size, hydrophilic glass fiber, 90 mm diameter

sterility

non-sterile

feature

hydrophilic

manufacturer/tradename

Millipore

parameter

1.4 mL/min-cm2 water flow rate, 500 °C max. temp.

diam.

90 mm

filter diam.

90 mm

thickness

380 μm

gravimetric extractables

300%

pore size

0.7 μm pore size, 90 % porosity

shipped in

ambient

General description

Overview
Millipore fibrous disc filters are available in a wide range of flow rates and throughput capacities. Our Glass Fiber filters are available with or without binder resins and can be sterilized by EO, gamma, or autoclave (121 °C at 1 bar).

Glass Fiber Filters with Binder Resin:
Millipore filters with binder resin have superior wet strength and are excellent for qualitative analysis and prefiltration, especially for heavily contaminated liquids. They are also widely used for clarification of aqueous solutions.

Type AP15
•Lowest dirt-holding capacity
•Recommended prefilter for 0.2 to 0.6 µm filters

Type AP20
•Lower retention, higher dirt-holding capacity than AP15 filters
•Recommended prefilter for 0.8 to 8.0 µm filters
•Use upstream to protect type AP15 filters

Type AP25
•Added thickness yields same retention and greater dirt-holding capacity as AP20
•Recommended prefilter for 0.9 to 8 µm filters, especially for proteinaceous and heavily contaminated liquids
•Use upstream to protect type AP15 filters

Glass Fiber Filters without Binder Resin:
The filters without binder resin retain their structural integrity without weight loss when heated up to 500 °C and can therefore be used in gravimetric analysis as well as for the filtration of hot gases.

Type APFA
•Retains fine particles with good efficiency, even at high flow rates
•Recommended for monitoring wastewater and collecting suspended particles in gases (e.g., fumes from chimneys)
•Use in biochemical applications (e.g., collection of cells and filtration of protein or nucleic acid precipitates)

Type APFB
•Higher mechanical strength when wet and greater loading capacity than type APFA filters
•Use for liquid clarification, quantification of solids in suspensions of fine particles, and scintillation counting

Type APFC
•Greater retention, especially for fine particulate and microorganism removal than type APFA filters
•Use for determining total suspended solids in drinking water
•Use for filtering proteins or nucleic acid TCA precipitates and for collecting cells and microorganisms

Type APFD
•Thick filter with high flow and low retention
•Use for clarifying suspensions containing particulates greater than 1.0 µm

Type APFF
•Use for filtering extremely fine precipitates such as protein, nucleic acids, or serum precipitates
•Recommended for USEPA method 1311 for TCLP analysis

Type AP40
•Recommended for Standard Methods Total Suspended Solids 2540D
•Recommended for USEPA method 1311 for TCLP analysis
•Maintains structural integrity without weight loss when ignited to 550 °C (1022 °F) after sample filtration
•Recommended for determining volatile suspended matter in wastewater and industrial effluents
Filter Code: APFF
Filter Type: Depth filter

Application

  • Filtering extremely fine precipitates
  • Filtration of protein, nucleic acids, or serum precipitates
  • EPA method 1311 for TCLP analysis
  • Microplastics analysis grade water


Confronta articoli simili

Visualizza il confronto per intero

Mostra le differenze

1 of 1

Questo articolo
APFF02500APFF04700APFF14250
description

Millipore, filter diam. 90 mm, hydrophilic, thickness 380 μm

description

Millipore, filter diam. 25 mm, hydrophilic, thickness 380 μm

description

Millipore, pore size 0.7 μm, hydrophilic, thickness 380 μm, pkg of 100 ea

description

Millipore, filter diam. 142 mm, hydrophilic, thickness 380 μm

parameter

1.4 mL/min-cm2 water flow rate, 500 °C max. temp.

parameter

1.4 mL/min-cm2 water flow rate, 500 °C max. temp.

parameter

1.4 mL/min-cm2 water flow rate, 500 °C max. temp.

parameter

1.4 mL/min-cm2 water flow rate, 500 °C max. temp.

pore size

0.7 μm pore size, 90 % porosity

pore size

0.7 μm pore size, 90 % porosity

pore size

0.7 μm pore size, 90 % porosity

pore size

0.7 μm pore size, 90 % porosity

diam.

90 mm

diam.

25 mm

diam.

-

diam.

142 mm

manufacturer/tradename

Millipore

manufacturer/tradename

Millipore

manufacturer/tradename

Millipore

manufacturer/tradename

Millipore

material

glass fiber membrane, white filter, plain filter

material

glass fiber membrane, plain filter, white filter

material

glass fiber membrane, plain filter, white filter

material

glass fiber membrane, plain filter, white filter

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile


Still not finding the right product?




Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documenti section.

Se ti serve aiuto, non esitare a contattarci Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti



Questions

Reviews

No rating value

Active Filters