B-035
Buprenorphine glucuronide solution
100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Sinonimo/i:
Buprenorphine-3-β-D-glucuronide solution
About This Item
Prodotti consigliati
Grado
certified reference material
Livello qualitativo
Forma fisica
liquid
Caratteristiche
SNAP-N-SPIKE®, SNAP-N-SHOOT®
Confezionamento
ampule of 1 mL
Produttore/marchio commerciale
Cerilliant®
drug control
Narcotic Licence Schedule A (Switzerland)
Concentrazione
100 μg/mL in methanol
tecniche
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
applicazioni
clinical testing
Formato
single component solution
Temperatura di conservazione
−20°C
Stringa SMILE
CO[C@]12CC[C@@]3(C[C@@H]1[C@](C)(O)C(C)(C)C)[C@H]4Cc5ccc(O[C@@H]6O[C@@H]([C@@H](O)[C@H](O)[C@H]6O)C(O)=O)c7O[C@@H]2[C@]3(CCN4CC8CC8)c57
InChI
1S/C35H49NO10/c1-31(2,3)32(4,42)20-15-33-10-11-35(20,43-5)30-34(33)12-13-36(16-17-6-7-17)21(33)14-18-8-9-19(26(46-30)22(18)34)44-29-25(39)23(37)24(38)27(45-29)28(40)41/h8-9,17,20-21,23-25,27,29-30,37-39,42H,6-7,10-16H2,1-5H3,(H,40,41)/t20-,21-,23+,24+,25-,27+,29-,30-,32+,33-,34+,35-/m1/s1
CZULHKGIAJASAA-WWIHBJMFSA-N
Categorie correlate
Descrizione generale
Applicazioni
- Simplified processing and rapid quantification of buprenorphine, norbuprenorphine, and their conjugated metabolites in human plasma using UPLC-MS/MS: This study underscores the importance of buprenorphine glucuronide as a standard in pharmacokinetic research, facilitating accurate assessments of buprenorphine exposure during opioid use disorder treatment (Zhao et al., 2024).
- Quantitative Analysis of Buprenorphine, Norbuprenorphine, and Their Glucuronide Metabolites in Human Urine: Highlights the application of buprenorphine glucuronide in developing methods for analyzing opioid metabolites in urine, crucial for monitoring drug therapy and compliance in clinical settings (Gqamana et al., 2024).
- Interaction between buprenorphine and norbuprenorphine in neonatal opioid withdrawal syndrome: The research uses buprenorphine glucuronide to study drug interactions in treating neonatal opioid withdrawal, demonstrating its significance in neonatal pharmacological research and therapy optimization (Tobacyk et al., 2023).
Note legali
Prodotti correlati
Avvertenze
Danger
Indicazioni di pericolo
Consigli di prudenza
Classi di pericolo
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
Organi bersaglio
Eyes
Codice della classe di stoccaggio
3 - Flammable liquids
Classe di pericolosità dell'acqua (WGK)
WGK 1
Punto d’infiammabilità (°F)
49.5 °F - closed cup
Punto d’infiammabilità (°C)
9.7 °C - closed cup
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Protocolli
Optimize β-glucuronidase hydrolysis for glucuronide metabolite analysis considering factors like time, temperature, pH, and enzyme concentration.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.