Passa al contenuto
Merck
Tutte le immagini(1)

Documenti

805998

Sigma-Aldrich

SYLGARD® 170 silicone elastomer

10 cc dual syringe with the static mixer

Sinonimo/i:

Curing agent, PDMS, Polydimethylsiloxane, Silicone, Silicone rubber

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
12162002
NACRES:
NA.23

Livello qualitativo

Descrizione

Form: Black liquid (part A), off-white liquid (part B)
Viscosity: 3160 cPs (part A), 1110 cPs (part B)

Forma fisica

liquid

Descrizione generale

Features:
  • Two-part: 1:1 mixing ratio (pre-weighed).
  • Low viscosity.
  • Room temperature or heat accelerated cure.
  • Rapid, versatile cure processing controlled by temperature.
  • Moderate thermal conductivity.
  • Enhanced flow and fill in narrow spaces and around complex geometries.
  • Provides stress relief in applications where hard, rigid encapsulants can cause damage during thermal cycling.
  • It can be considered for uses requiring added flame resistance and Mil Spec applications.

How to use:
Mixing: SYLGARD® 170 Silicone Elastomer is supplied in a dual syringe applicator with the static mixer consisting of Part A and Part B. The two components pre-weighed with 1:1 mixing ratio in the syringe applicator should be thoroughly mixed until the mixture has a uniform color. Vacuum de-airing is recommended. A residual pressure of 10-20 mmHg applied for 5-10 minutes will sufficiently de-air the material.

Curing: SYLGARD® 170 Silicone Elastomer should be cured using one of the following recommended schedules:
  • 24 hours at 25°C or
  • 25 minutes at 70°C or
  • 10 minutes at 100°C.

Large components and assemblies may require longer times in order to reach the curing temperature.
Certain chemicals, curing agents and plasticizers can inhibit cure. These include:
  • Organo-tin compounds.
  • Silicone rubber containing organo-tin catalysts.
  • Sulfur, polysulphides, polysulphones and other sulphur containing materials.
  • Amines, urethanes, amides and azides.

For most uses, silicone encapsulants should be operational over a temperature range of -45 to 200°C (-49 to 392°F) for long periods of time.

Applicazioni

SYLGARD® 170 Silicone Elastomer is suitable for use as an encapsulant or potting material.

Potential applications:
  • Power supplies
  • Connectors
  • Sensors
  • Industrial controls
  • Transformers
  • Amplifiers
  • High voltage resistor packs
  • Relays

Nota sulla preparazione

MIXING AND DE-AIRING - These products are supplied in a 1 to 1 mix ratio, which is very robust in manufacturing environments and allows for some process and dispense equipment variation. In most cases de-airing is not required. PREPARING SURFACES - In applications requiring adhesion, priming will be required for many of the silicone encapsulants. For best results, the primer should be applied in a very thin, uniform coating and then wiped off after application. After application, it should be thoroughly cured prior to application of the silicone elastomer. Additional instructions for primer usage can be found in the information sheets specific to the individual primers.

PROCESSING/CURING - Thoroughly mixed Dow silicone encapsulants may be poured/dispensed directly into the container in which it is to be cured. Care should be taken to minimize air entrapment. When practical, pouring/dispensing should be done under vacuum, particularly if the component being potted or encapsulated has many small voids. If this technique cannot be used, the unit should be evacuated after the silicone encapsulant has been poured/ dispensed. Dow silicone encapsulants may be either room temperature (25°C/77°F) or heat cured. Room temperature cure encapsulants may also be heat accelerated for faster cure. Ideal cure conditions for each product are given in the product selection table.

POT LIFE AND CURE RATE - Cure reaction begins with the mixing process. Initially, cure is evidenced by a gradual increase in viscosity, followed by gelation and conversion to a solid elastomer. Pot life is defined as the time required for viscosity to double after Parts A and B (base and curing agent) are mixed and is highly temperature and application dependent.

USEFUL TEMPERATURE RANGES - For most uses, silicone encapsulants should be operational over a temperature range of -45 to 200°C (-49 to 392°F) for long periods of time. However, at both the low- and high temperature ends of the spectrum, behavior of the materials and performance in particular applications can become more complex and require additional considerations and should be adequately tested for the particular end use environment. For low-temperature performance, thermal cycling to conditions such as -55°C (-67°F) may be possible, but performance should be verified for your parts or assemblies. Factors that may influence performance are configuration and stress sensitivity of components, cooling rates and hold times, and prior temperature history. At the high temperature end, the durability of the cured silicone elastomer is time and temperature dependent. As expected, the higher the temperature, the shorter the time the material will remain useable.

COMPATIBILITY - Certain materials, chemicals, curing agents and plasticizers can inhibit the cure of addition cure gels. Most notable of these include: organotin and other organometallic compounds, silicone rubber containing organotin catalyst, sulfur, polysulfides, polysulfones or other sulfur containing materials, unsaturated hydrocarbon plasticizers, and some solder flux residues. If a substrate or material is questionable with respect to potentially causing inhibition of cure, it is recommended that a small scale compatibility test be run to ascertain suitability in a given application. The presence of liquid or uncured product at the interface between the questionable substrate and the cured gel indicates incompatibility and inhibition of cure.

Note legali

Sylgard is a registered trademark of The Dow Chemical Company or an affiliated company of Dow

Codice della classe di stoccaggio

12 - Non Combustible Liquids

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Andrew G Gillies et al.
ACS applied materials & interfaces, 5(13), 6081-6088 (2013-06-22)
Recently, gecko-inspired synthetic adhesives (GSAs) have been made using a variety of fabrication techniques and materials, with one made from a hard polymer having been reported to recover its shear adhesion after fouling by normal use, or "dry self-clean", a
Audrey M Bowen et al.
Small (Weinheim an der Bergstrasse, Germany), 7(23), 3350-3362 (2011-10-15)
A method for fabricating chemical gradients on planar and nonplanar substrates using grayscale lithography is reported. Compliant grayscale amplitude masks are fabricated using a vacuum-assisted microfluidic filling protocol that employs dilutions of a carbon-black-containing polydimethylsiloxane emulsion (bPDMS) within traditional clear
Direction specific adhesion induced by subsurface liquid filled microchannels.
Majumder A, et al.
Soft Matter, 8(27), 7228-7233 (2012)

Contenuto correlato

We offer PDMS surface modification kit which allows for durable hydrophilization of various polydimethylsiloxane (PDMS) surfaces.

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.