Self-made microextraction by packed sorbent device for the cleanup of polychlorinated biphenyls from bovine serum.

Journal of separation science (2016-02-24)
Liu Yang, Qiang Han, Shuya Cao, Junchao Yang, Jiang Zhao, Molin Qin, Mingyu Ding
RÉSUMÉ

Microextraction by packed sorbent, a miniaturized form of the solid-phase extraction, is a new sample pretreatment technology mainly used for bioanalysis. In this work, self-made device was fabricated by packing C18 sorbent into a microinjection needle (50 μL) and then applied for the analysis of polychlorinated biphenyls in bovine serum followed by gas chromatography with mass spectrometry determination. Compared with conventional solid-phase extraction, the developed method bears many intriguing properties such as low consumption of the sample and organic solvent, time-saving and easy operation, which are of great interest and desire for bioanalysis applications. A series of parameters that affect the analytical performance, such as the type of elution, the aspirating/dispensing cycles of sample loading and elution, washing solution, and matrix effects, was investigated in detail. Under the optimized conditions, the proposed method presented a good linearity (R ≥ 0.986) and satisfactory sensitivity and limits of detection (0.06-0.53 ng/mL) and quantification (0.20-1.77 ng/mL), respectively. In addition, satisfactory recoveries (60.0-91.4%) and accuracy (RSD ≤ 5.72%) were achieved after optimizing the conditions when applying the developed method to real sample analysis. The screening of polychlorinated biphenyls residues in bovine serum samples by the developed method demonstrated that the assay is ideally suited as a monitoring method for polychlorinated biphenyls residues in bioanalysis.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Supelco
Ensemble de fibres de SPME, divinylbenzène/carboxène/polydiméthylsiloxane (DVB/CAR/PDMS), matrix active group 50/30µm DVB/CAR/PDMS, needle size 24 ga, StableFlex fiber, for use with autosampler, fiber L 2 cm, pk of 3
Supelco
Ensemble de fibres de SPME, divinylbenzène/carboxène/polydiméthylsiloxane (DVB/CAR/PDMS), matrix active group 50/30µm DVB/CAR/PDMS, StableFlex fiber, manual holder, needle size 24 ga
Supelco
Ensemble de fibres de SPME, divinylbenzène/carboxène/polydiméthylsiloxane (DVB/CAR/PDMS), 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, plain gray hub
Supelco
Ensemble de fibres de SPME, divinylbenzène/carboxène/polydiméthylsiloxane (DVB/CAR/PDMS), matrix active group 50/30µm DVB/CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler, fiber L 1 cm, pk of 3
Supelco
Ensemble de fibres de SPME, divinylbenzène/carboxène/polydiméthylsiloxane (DVB/CAR/PDMS), 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 23 ga, Autosampler, pk of 3, notched gray hub
Supelco
Fibres SPME polydiméthylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
Fibres SPME polydiméthylsiloxane (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
Fibres SPME polydiméthylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Fibres SPME polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
Fibres SPME polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
Fibres SPME polydiméthylsiloxane (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
Kit d'assortiment de fibres SPME StableFlex, for use with manual holder
Supelco
SPME fiber assembly, Carbowax-Polyethylene Glycol (PEG) Coating, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
Kit d'assortiment de fibres SPME StableFlex, needle size 23 ga, StableFlex fiber, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
Ensemble de fibres de SPME, divinylbenzène/carboxène/polydiméthylsiloxane (DVB/CAR/PDMS), for use with autosampler, matrix active group 50/30µm DVB/CAR/PDMS, needle size 23 ga, metal alloy fiber, fiber L 2 cm
Supelco
Fibres SPME polyacrylate (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga