Accéder au contenu
Merck
Toutes les photos(1)

Documents

15614

Sigma-Aldrich

Hexamethylenetetramine

meets analytical specification of Ph. Eur., BP, 99-100.5% (calc. to the dried substance)

Synonyme(s) :

1,3,5,7-Tetraazatricyclo[3.3.1.13,7]decane, Hexamine, Methenamine, Urotropine

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill):
C6H12N4
Numéro CAS:
Poids moléculaire :
140.19
Numéro Beilstein :
2018
Numéro CE :
Numéro MDL:
Code UNSPSC :
12352116
ID de substance PubChem :
Nomenclature NACRES :
NA.21

Pression de vapeur

<0.01 mmHg ( 20 °C)

Niveau de qualité

Pureté

99-100.5% (calc. to the dried substance)

Forme

solid

Température d'inflammation spontanée

770 °F

Qualité

meets analytical specification of Ph. Eur., BP

Impuretés

acidic and alkalic reac. substances, complies
residual solvents, in accordance
≤0.002% heavy metals (as Pb)
≤0.005% free formaldehyde

Perte

≤2% loss on drying

Pf

280 °C (subl.) (lit.)

Solubilité

H2O: soluble

Traces d'anions

chloride (Cl-): ≤100 mg/kg
sulfate (SO42-): ≤100 mg/kg

Adéquation

complies for appearance of solution

Application(s)

pharmaceutical (small molecule)

Chaîne SMILES 

C1N2CN3CN1CN(C2)C3

InChI

1S/C6H12N4/c1-7-2-9-4-8(1)5-10(3-7)6-9/h1-6H2

Clé InChI

VKYKSIONXSXAKP-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Pictogrammes

FlameExclamation mark

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Flam. Sol. 2 - Skin Sens. 1B

Code de la classe de stockage

4.1B - Flammable solid hazardous materials

Classe de danger pour l'eau (WGK)

WGK 1

Point d'éclair (°F)

482.0 °F - closed cup

Point d'éclair (°C)

250 °C - closed cup

Équipement de protection individuelle

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges


Choose from one of the most recent versions:

Certificats d'analyse (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

E M Rodríguez et al.
Histochemistry, 81(3), 253-263 (1984-01-01)
The use of butyl-methyl-methacrylate embedding and the application of the silver methenamine (SM) method as a poststaining of the immunoperoxidase-DAB (IP) procedure led to the standardization of several useful methods for the visualization of tissue antigens at the light and
Enhanced quantum dot deposition on ZnO nanorods for photovoltaics through layer-by-layer processing.
<BIG>Joe Briscoe</BIG>
Journal of Materials Chemistry, 2517-2523 (2011)
Ann Pontén et al.
Contact dermatitis, 68(1), 50-53 (2012-10-06)
The currently used patch test concentration for formaldehyde is 1.0% (wt/vol) in water. However, clinical experience and previous studies suggest that 1.0% might be insufficient for detecting an optimized number of clinically relevant cases of contact allergy to formaldehyde. To
Jianguo Hu et al.
Talanta, 93, 345-349 (2012-04-10)
A green, one-step method for synthesis of graphene-Au nanoparticles (graphene-AuNPs) was introduced in this article, using an environmentally benign hexamethylenetetramine (HMTA) as reducing and stabilizing agent. HMTA slowly was hydrolyzed to generate aldehyde ammonia to reduce graphene oxides (GO) and
Erin M Warshaw et al.
Journal of the American Academy of Dermatology, 66(2), 229-240 (2011-05-21)
Relatively little is known about the epidemiology of allergic contact dermatitis in older individuals. We sought to determine the frequency of positive and clinically relevant patch test reactions in older individuals (≥ 65 years old) referred for patch testing, and

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique