KVVLS10HH1
Durapore® 0,1 µm, capsule Opticap® XL
sterile, Opticap® XL 10, inlet connection diam. 9/16 in., cartridge nominal length 10 in. (25 cm)
Synonyme(s) :
Sterile Opticap XL 10 w/Phil Dur - 10" 0.1 μm HB/HB 1pk
About This Item
Produits recommandés
Matériaux
PVDF
polyester support
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap
silicone outer O-ring
silicone-coated EPDM rubber lead O-ring
Niveau de qualité
Conformité réglementaire
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
Stérilité
irradiated
sterile
Gamme de produits
Opticap® XL 10
Caractéristiques
hydrophilic
Fabricant/nom de marque
Opticap®
Paramètres
1.0 bar max. inlet pressure (15 psi) at 80 °C
1.7 bar max. differential pressure (25 psid) at 80 °C (Forward)
2.8 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
Technique(s)
sterile filtration: suitable
Longueur
33.5 cm (13.2 in.)
Longueur nominale des cartouches
10 in. (25 cm)
Diamètre
10.7 cm (4.2 in.)
Surface de filtration
0.73 m2
Diam. du raccord d'entrée
9/16 in.
Largeur, de l'entrée à la sortie
33.5 cm (13.2 in.)
Diam. du raccord de sortie
9/16 in.
Impuretés
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Extractibles par gravimétrie
≤25 mg/capsule
Matrice
Durapore®
Dimension de pores
0.1 μm
Entrée
sample type liquid
Point de bulle
≥4830 mbar (70 psig), air with water at 23 °C
Raccords
1/4 in. drain/vent hose barb (with double O-ring Seal)
inlet hose barb
outlet hose barb
(14 mm (9/16 in.) Hose Barb Inlet and Outlet)
Description générale
Conditionnement
Autres remarques
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Notes préparatoires
Shipped sterile by gamma irradiation @ >25 kGray gamma exposure
Remarque sur l'analyse
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Informations légales
Clause de non-responsabilité
Not finding the right product?
Try our Outil de sélection de produits.
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique