KVGBA10HH1
Membrane Durapore® hydrophobe de 0,22 µm, Capsule Opticap® XL
inlet connection diam. 9/16 in., Opticap® XL 10, pore size 0.22 μm, cartridge nominal length 10 in. (25 cm)
Synonyme(s) :
Opticap Sterilizing Grade XL10 Durapore Hydrophobic 0.22 µm 9/16 in. HB/HB
About This Item
Produits recommandés
Matériaux
PVDF
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
silicone seal
Niveau de qualité
Conformité réglementaire
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
Stérilité
non-sterile
Mode de stérilisation compatible
autoclavable compatible
Gamme de produits
Opticap® XL 10
Caractéristiques
hydrophobic
Fabricant/nom de marque
Opticap®
Paramètres
≤10 mL/min nitrogen diffusion at 1.7 bar (25 psig) and 23 °C (with 60/40% IPA/water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.8 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.4 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
Technique(s)
sterile filtration: suitable
Longueur
13.2 in.
Largeur
4.2 in.
Longueur nominale des cartouches
10 in. (25 cm)
Diamètre
14.5 cm (5.7 in.)
Surface de filtration
0.69 m2
Diam. du raccord d'entrée
9/16 in.
Largeur, de l'entrée à la sortie
33.3 cm (13.1 in.)
Diam. du raccord de sortie
9/16 in.
Impuretés
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Matrice
Durapore®
Dimension de pores
0.22 μm pore size
Point de bulle
≥1240 mbar (18 psig), nitrogen with 60/40% IPA/water at 23 °C
Raccords
1/4 in. drain/vent hose barb (with double O-ring Seal)
(14 mm (9/16 in.) Hose Barb Inlet and Outlet)
Description générale
Conditionnement
Autres remarques
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Notes préparatoires
20 autoclave cycles of 30 min @ 126 °C; not in-line steam sterilizable
Remarque sur l'analyse
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Informations légales
Clause de non-responsabilité
Vous ne trouvez pas le bon produit ?
Essayez notre Outil de sélection de produits.
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique