Accéder au contenu
Merck
Toutes les photos(2)

Key Documents

HTS041M

Sigma-Aldrich

ChemiScreen Bradykinin B2 Membrane Preparation

Human B2 GPCR membrane preparation for Radioligand binding Assays & GTPgammaS binding.

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41106514
eCl@ss :
32161000
Nomenclature NACRES :
NA.41

Source biologique

human

Niveau de qualité

Produit recombinant

expressed in Chem-1 cells

Conditionnement

pkg of 1 mL

Fabricant/nom de marque

ChemiScreen
Chemicon®

Concentration

0.5 mg/mL (per vial)

Technique(s)

ligand binding assay: suitable (GTPγS)
radioligand binding assay (RLBA): suitable

Numéro d'accès NCBI

Numéro d'accès UniProt

Conditions d'expédition

dry ice

Informations sur le gène

human ... BDKRB2(624)

Description générale

Bradykinins bind and activate two GPCRs, termed B1 and B2 (gene names BDKRB1 and BDKRB2, respectively), which signal through Gq and Gi. B2 is widely expressed in a constitutive fashion, whereas B1 expression is induced during inflammation. B2 appears to mediate much of the activity of kinins in vasodilation, arthritis, edema, and nociception (Leeb-Lundberg et al., 2005). Chemicon′s B2 membrane preparations are crude membrane preparations made from our proprietary stable recombinant cell lines to ensure high-level of GPCR surface expression; thus, they are ideal HTS tools for screening of antagonists of B2 interactions with bradykinin. The membrane preparations exhibit a Kd of 0.18 nM for [3H]-bradykinin. With 5.0 μg/well, B2 Membrane Prep and 0.4 nM [3H]-bradykinin, a greater than 4-fold signal-to-background ratio is obtained.
Full length Human BDKRB2

Application

Radioligand binding assay, and GTPgammaS binding

Actions biochimiques/physiologiques

GPCR Class: A
Protein Target: B2
Target Sub-Family: Bradykinin

Qualité

SPECIFICATIONS: 1 unit = 10 µg
Bmax: 2.73 pmol/mg
Kd: 0.18 nM

Caractéristiques

Inucbation Conditions
RECOMMENDED ASSAY CONDITIONS: Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, a GF/C 96-well filter plate is coated with 0.33% polyethyleneimine for 30 min, then washed with 50mM HEPES, pH 7.4, 0.5% BSA. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer. The plate is dried and counted.

Binding buffer: 50 mM Hepes, pH 7.4, 5 mM MgCl2, 1 mM CaCl2, 0.2% BSA, filtered and stored at 4°C

Radioligand: [3H] Bradykinin, [2,3-prolyl-3,4-3H(N)] (Perkin Elmer #NET-706)

Wash Buffer: 50 mM Hepes, pH 7.4, 500 mM NaCl , 0.1% BSA, filtered and stored at 4°C.

One package contains enough membranes for at least 200 assays (units), where a unit is the amount of membrane that will yield greater than 4-fold signal:background with 3H-labeled bradykinin at 0.4 nM

Forme physique

Liquid in packaging buffer: 50 mM Tris pH 7.4, 10% glycerol and 1% BSA with no preservatives.

Packaging method: Membranes protein were adjusted to the indicated concentration in packaging buffer, rapidly frozen, and stored at -80°C.

Stockage et stabilité

Maintain frozen at -70°C for up to 2 years. Do not freeze and thaw.

Informations légales

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Code de la classe de stockage

12 - Non Combustible Liquids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique