HLPPMAG-57K
MILLIPLEX® Human Liver Protein Magnetic Bead Panel - Metabolism Multiplex Assay
The Human Liver Protein Panel, using the Luminex xMAP technology, enables the simultaneous analysis of 9 liver protein biomarkers in human serum, plasma and tissue/cell culture samples.
About This Item
Produits recommandés
Niveau de qualité
Espèces réactives
human
Fabricant/nom de marque
Milliplex®
assay range
accuracy: 100.2%
(HGF)
accuracy: 93.7%
(ANGPTL3)
accuracy: 94.2%
(AFP)
accuracy: 96.6%
(FGF-23)
accuracy: 96.8%
(ANGPTL4)
accuracy: 98.8%
(FGF-21)
sensitivity: 0.004 ng/mL
(MinDC+2SD; FGF-21)
sensitivity: 0.014 ng/mL
(MinDC+2SD; FGF-23)
sensitivity: 0.018 ng/mL
(MinDC+2SD; HGF)
sensitivity: 0.054 ng/mL
(MinDC+2SD; FGF-19)
sensitivity: 0.144 ng/mL
(MinDC+2SD; AFP)
sensitivity: 0.218 ng/mL
(MinDC+2SD; FABP1)
sensitivity: 0.725 ng/mL
(MinDC+2SD; ANGPTL3)
sensitivity: 0.847 ng/mL
(MinDC+2SD; ANGPTL6)
sensitivity: 2.150 ng/mL
(MinDC+2SD; ANGPTL4)
standard curve range: 0.01-10 ng/mL
(FGF-21)
standard curve range: 0.04-30 ng/mL
(FGF-23)
standard curve range: 0.07-50 ng/mL
(HGF)
standard curve range: 0.14-100 ng/mL
(AFP)
standard curve range: 0.14-100 ng/mL
(FGF-19)
standard curve range: 0.27-200 ng/mL
(FABP1)
standard curve range: 0.69-500 ng/mL
(ANGPTL3)
standard curve range: 1.37-1000 ng/mL
(ANGPTL6/AGF)
standard curve range: 5.49-4000 ng/mL
(ANGPTL4)
inter-assay cv: <20%
intra-assay cv: <10%
(AFP)
inter-assay cv: <20%
intra-assay cv: <10%
(ANGPTL3)
inter-assay cv: <20%
intra-assay cv: <10%
(ANGPTL4)
inter-assay cv: <20%
intra-assay cv: <10%
(ANGPTL6/AGF)
inter-assay cv: <20%
intra-assay cv: <10%
(FABP1)
inter-assay cv: <20%
intra-assay cv: <10%
(FGF-19)
inter-assay cv: <20%
intra-assay cv: <10%
(FGF-21)
inter-assay cv: <20%
intra-assay cv: <10%
(FGF-23)
inter-assay cv: <20%
intra-assay cv: <10%
(HGF)
Technique(s)
multiplexing: suitable
Méthode de détection
fluorometric (Luminex xMAP)
Conditions d'expédition
wet ice
Description générale
MILLIPLEX® Human Liver Protein Panel is a 9-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma and tissue/cell culture samples: AFP, ANGPTL3, ANGPTL4, ANGPTL6/AGF, FABP1/L-FABP, FGF-19, FGF-21, FGF-23 and HGF.
NOTE: When assaying ANGPTL6/AGF it is recommended that serum samples be used.
This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Metabolism
Spécificité
The ANGPTL6 standard had cross reactivity with the ANGPTL4 assay of less than 2%. For all other analytes, there was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
Application
- Analytes: α-Fetoprotein (AFP), ANGPTL3, ANGPTL4, ANGPTL6 (AGF), FABP1 (L-FABP), FGF-19, FGF-21, FGF-23, HGF
- Recommended Sample Type: Human serum, plasma, and cell/tissue culture supernatants or lysates
- NOTE: Serum samples are recommended when measuring ANGPTL6/AGF
- Recommended Sample Dilution: 12.5 μL per well of 1:2 diluted serum or plasma. Cell/tissue culture samples may be used undiluted or appropriately diluted in control medium.
- Assay Run Time: Overnight (16-18 hours) at 2-8°C is recommended for optimal sensitivity. 2 hours at room temperature (20-25° C) may also be used.
- Research Category: Metabolism
- Research Subcategory: Metabolic Disorders
Caractéristiques et avantages
Conditionnement
Stockage et stabilité
Autres remarques
Informations légales
Clause de non-responsabilité
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1
Code de la classe de stockage
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Contenu apparenté
UnEnhance research with MILLIPLEX® multiplexing tips, industry guidance, and one-day assays for limited lab time.
Multiplex immunoassays save time and sample volume in metabolic syndrome research, providing comprehensive insights into related conditions.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..