Accéder au contenu
Merck
Toutes les photos(1)

Documents

CWLC72S03

Millipore

Milligard® LPB 1.2/0.5 µm nominal, Cartridge

cartridge nominal length 20 in. (50 cm), filter diam. 2.8 in. (7.1 cm)

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
23151806

Matériaux

polyester support
polypropylene device
silicone seal

Niveau de qualité

Stérilité

non-sterile

Mode de stérilisation compatible

autoclavable compatible
steam-in-place compatible

Gamme de produits

Milligard®

Caractéristiques

hydrophilic

Fabricant/nom de marque

Milligard®

Paramètres

3.5 bar max. differential pressure (50 psid) at 25 °C
3.5 bar max. inlet pressure (50 psi) at 25 °C

Technique(s)

prefiltration: suitable

Longueur

20 in.

Largeur

2.9 in.

Longueur nominale des cartouches

20 in. (50 cm)

Diam. du filtre

2.8 in. (7.1 cm)

Taille du filtre

20 in.

Surface de filtration

1.4 m2

Impuretés

≤0.5 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

Matrice

Milligard® LPB

pore size

1.2/0.5 μm nominal pore size
1.2/0.5 μm pore size

Code de la cartouche

Code 7

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Cartridge Type: Liquid
Device Configuration: Cartridge
Filter Grade: Low Protein Binding MILLIGARD® Media

Caractéristiques et avantages

Format: Double Layer

Conditionnement

Double Easy-Open bag

Notes préparatoires

Sterilization Method: 10 autoclave cycles or SIP at 121 °C for 30 min

This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Remarque sur l'analyse

Gravimetric Extractables: The extractables level was ≤350 mg per 10-inch cartridge after a 5 L flush and 24 hours in water at controlled room temperature.

Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L  

Autres remarques

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation and wetting sections of OPTISCALE® -25 user guide and introduction section of Mixed cellulose esters Tech Brief
  • Storage Statement: Please refer Mixed cellulose esters Tech Brief
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Informations légales

MILLIGARD is a registered trademark of Merck KGaA, Darmstadt, Germany
OptiScale is a registered trademark of Merck KGaA, Darmstadt, Germany

Not finding the right product?  

Try our Outil de sélection de produits.


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique