Accéder au contenu
Merck
Toutes les photos(1)

Documents

03-0187-00

Millipore

SMC® Human MCP-1 High Sensitivity Immunoassay Kit

Synonyme(s) :

MCP 1 immunoassay kit, MCP-1 Single Molecule Counting Kit, MCP-1 ultra-sensitive immunoassay, Monocyte Chemoattractant Protein-1 immunoassay kit

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12161503
Nomenclature NACRES :
NA.84

Fabricant/nom de marque

SMC®

assay range

sensitivity: 0.15 pg/mL
(Lower Limit of Quantification)

inter-assay cv: 4%
intra-assay cv: 5%
(five normal plasma samples run in triplicate by 3 different operators on 3 different days.)

Technique(s)

single molecule counting: suitable

Température de stockage

2-8°C

Spécificité

Species Reactivity:
Specificity to the following species analytes were tested with the following results:
Rat – Not cross-reactive
Mouse – Not cross-reactive
Canine – Not cross-reactive

Cross Reactivity:
Cross-reactivity to the following analytes were tested with the following results:
MCP-2 – Not cross-reactive
MCP-3 – Not cross-reactive

Accuracy:
  • Minimum of 5 serum samples spiked with average recovery of 104% with a range of 92-115%
  • Minimum of 5 plasma samples spiked with average recovery of 101% with a range of 80-123%

Application

The sensitivity of the Single Molecule Counting (SMC®) technology gives the SMC® Human MCP-1 High Sensitivity Immunoassay Kit unparalleled performance in the quantification of MCP-1 in human serum and plasma.

This new streamline kit has the following features including:
  • Improved options for sample prep and incubation
  • Lyophilization of the standard provides the kit at one storage condition
  • Removal of a plate transfer step
  • Increased reagent volumes to accommodate automation
  • Validated to run on both SMCxPRO® and Erenna


Research Category:

Inflammation & Immunology

Research Sub-Category:
  • Inflammatory Disease
  • Immune Response
  • Autoimmune disease

Conditionnement

96 well assay

Composants

  • Assay Buffer
  • MCP-1 Coated Beads
  • Standard Diluent
  • MCP-1 Detection Antibody
  • MCP-1 Standard
  • 10X Wash Buffer
  • Buffer D
  • Elution Buffer B

Informations légales

SMC is a registered trademark of Singulex
SMCxPRO is a registered trademark of Merck KGaA, Darmstadt, Germany

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Pictogrammes

Skull and crossbonesHealth hazard

Mention d'avertissement

Danger

Classification des risques

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Repr. 1B

Code de la classe de stockage

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Contenu apparenté

Use the power of high sensitivity immunology assays with SMC® technology to precisely characterize low-abundant cytokines like those from Th1/Th2 and Th17 cells.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique