Accéder au contenu
Merck
Toutes les photos(1)

Principaux documents

W244601

Sigma-Aldrich

Ethyl nitrite solution

10-20 wt. % in ethanol

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
C2H5ONO
Numéro CAS:
Poids moléculaire :
75.07
Numéro MDL:
Numéro Flavis :
16.017

Source biologique

synthetic

Conformité réglementaire

FDA 21 CFR 172.515

Concentration

10-20 wt. % in ethanol

Indice de réfraction

n20/D 1.360

Densité

0.792 g/mL at 25 °C

Propriétés organoleptiques

nearly

Chaîne SMILES 

CCON=O

InChI

1S/C2H5NO2/c1-2-5-3-4/h2H2,1H3

Clé InChI

QQZWEECEMNQSTG-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Pictogrammes

FlameExclamation mark

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Eye Irrit. 2 - Flam. Liq. 2

Code de la classe de stockage

3 - Flammable liquids

Classe de danger pour l'eau (WGK)

WGK 1

Point d'éclair (°F)

59.0 °F - closed cup

Point d'éclair (°C)

15 °C - closed cup

Équipement de protection individuelle

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

J C MacDonald et al.
Acta chemica Scandinavica. Series B: Organic chemistry and biochemistry, 35(7), 485-487 (1981-01-01)
Gas chromatography--mass spectrometry demonstrates the presence of ethyl nitrite in the breath of volunteers subjects who smoke and drink concurrently. The mutagenic compound is quantitated at the ppb level by gas chromatography with the selective electron capture detector. The compound
Alessio Baccarani et al.
Journal of reconstructive microsurgery, 23(5), 257-262 (2007-09-19)
Vasospasm leading to thrombosis is a major cause of free flap failure. Flap blood flow may improve by application of vasodilating agents to the pedicle. The purpose of this study is to evaluate the effect of a novel S-nitrosylating agent
Martin P Moya et al.
Lancet (London, England), 360(9327), 141-143 (2002-07-20)
Inhaled nitric oxide is used to alleviate pulmonary hypertension and hypoxaemia, but generates toxic free radicals and oxides of nitrogen (NO(x)), which can cause rebound-hypoxia and additional pulmonary and other morbidity. To address these problems, we assessed the efficacy of
Basil M Yurcisin et al.
Annals of surgery, 257(5), 971-977 (2013-01-31)
To determine if reduction in nitric oxide bioactivity contributes to the physiological instability that occurs after brain death and, if so, to also determine in this setting whether administration of a renitrosylating agent could improve systemic physiological status. Organ function
Richard L Auten et al.
American journal of respiratory and critical care medicine, 176(3), 291-299 (2007-05-05)
Inhaled nitric oxide (NO) has been used to prevent bronchopulmonary dysplasia, but with variable results. Ethyl nitrite (ENO) forms S-nitrosothiols more readily than does NO, and resists higher-order nitrogen oxide formation. Because S-nitrosylation is a key pathway mediating many NO

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique