Accéder au contenu
Merck
Toutes les photos(2)

Documents

333824

Sigma-Aldrich

2,3,4-Trifluorobenzoic acid

98%

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
F3C6H2CO2H
Numéro CAS:
Poids moléculaire :
176.09
Numéro MDL:
Code UNSPSC :
12352100
ID de substance PubChem :
Nomenclature NACRES :
NA.22

Pureté

98%

Pf

140-142 °C (lit.)

Chaîne SMILES 

OC(=O)c1ccc(F)c(F)c1F

InChI

1S/C7H3F3O2/c8-4-2-1-3(7(11)12)5(9)6(4)10/h1-2H,(H,11,12)

Clé InChI

WEPXLRANFJEOFZ-UHFFFAOYSA-N

Description générale

Raman and FTIR spectra for 2,3,4-tri-fluoro-benzoic acid has been studied.

Pictogrammes

Exclamation mark

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

Organes cibles

Respiratory system

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

dust mask type N95 (US), Eyeshields, Gloves


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

V Mukherjee et al.
Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy, 74(5), 1107-1114 (2009-10-24)
Raman and FTIR spectra for 2,3,4-tri-fluoro-benzoic acid molecules have been recorded in the regions 50-4000 cm(-1) and 400-4000 cm(-1) respectively. The geometrical parameters have been optimized in both the monomeric and dimeric forms while vibrational frequencies have been calculated in
Jihye Kim et al.
Analytical and bioanalytical chemistry, 411(5), 1067-1073 (2018-12-20)
Single-drop microextraction (SDME) and large-volume sample stacking using an electroosmotic flow pump (LVSEP) were coupled with capillary electrophoresis/mass spectrometry (CE/MS) for sample cleanup and preconcentration. Without filtration or centrifugation of a soil sample containing debris, SDME using a pentanol acceptor

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique