Accéder au contenu
Merck
Toutes les photos(1)

Documents

112437

Sigma-Aldrich

4-Ethylpyridine

98%

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill):
C7H9N
Numéro CAS:
Poids moléculaire :
107.15
Numéro Beilstein :
106481
Numéro CE :
Numéro MDL:
Code UNSPSC :
12352100
ID de substance PubChem :
Nomenclature NACRES :
NA.22

Niveau de qualité

Pureté

98%

Indice de réfraction

n20/D 1.501 (lit.)

Point d'ébullition

168 °C (lit.)

Densité

0.942 g/mL at 25 °C (lit.)

Chaîne SMILES 

CCc1ccncc1

InChI

1S/C7H9N/c1-2-7-3-5-8-6-4-7/h3-6H,2H2,1H3

Clé InChI

VJXRKZJMGVSXPX-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Catégories apparentées

Description générale

4-Ethylpyridine undergoes metal-ligand interaction with Zn-porphyrin which can be studied by mass spectrometry.

Application

4-Ethylpyridine is used to study the influence of counter-anion concentration on analyte retention.

Pictogrammes

FlameExclamation mark

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Eye Irrit. 2 - Flam. Liq. 3 - Skin Irrit. 2 - STOT SE 3

Organes cibles

Respiratory system

Code de la classe de stockage

3 - Flammable liquids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

122.0 °F - closed cup

Point d'éclair (°C)

50 °C - closed cup

Équipement de protection individuelle

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

R LoBrutto et al.
Journal of chromatography. A, 913(1-2), 189-196 (2001-05-18)
The influence of acid and salt concentration in the mobile phase on the retention of basic analytes has been studied. An increase in the retention of fully protonated analytes with increasing the concentration of inorganic additives was found. The addition
Monica Brivio et al.
Lab on a chip, 5(10), 1111-1122 (2005-09-22)
Two simple interfaces were designed and realized, enabling on-line coupling of microfluidics reactor chips to a nanoflow electrospray ionization (NESI) time-of-flight (TOF) mass spectrometer (MS). The interfaces are based on two different approaches: a monolithically integrated design, in which ionization
Slavko Klobčar et al.
Biomedical chromatography : BMC, 29(12), 1901-1906 (2015-05-27)
The isolation of four oxidative degradation products of atorvastatin using preparative high-performance liquid chromatography applying at least two chromatographic steps is known from the literature. In this paper it is shown that the same four impurities could be isolated from
Michael Wleklinski et al.
Physical chemistry chemical physics : PCCP, 17(28), 18364-18373 (2015-06-25)
Electrospray ionization of metal salt solutions followed by ambient heating transforms the resulting salt clusters into new species, primarily naked ionic metal clusters. The experiment is done by passing the clusters through a heated coiled loop outside the mass spectrometer
Alexandre Grand-Guillaume Perrenoud et al.
Journal of chromatography. A, 1360, 275-287 (2014-08-19)
Superficially porous particles (SPP), or core shell particles, which consist of a non-porous silica core surrounded by a thin shell of porous silica, have gained popularity as a solid support for chromatography over the last decade. In the present study

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique