20652

Septa Thermogreen® LB-2, disques solides

diam. 9.5 mm ( 3/8 in.), pkg of 50 ea

Se connecter pour consulter les tarifs organisationnels et contractuels.

Sélectionner une taille de conditionnement

Changer de vue

A propos de cet article

UNSPSC Code:
41115718
NACRES:
SB.54
Packaging:
pkg of 50 ea
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider


packaging

pkg of 50 ea

technique(s)

gas chromatography (GC): suitable using :Suitable

diam.

9.5 mm ( 3/8 in.)

compatibility

for use with Agilent/HP 5700 Series, 5830, 5840, for use with Finnigan 9600, for use with GOW-MAC® all, for use with HNU portable GC, for use with Tracor 550, 560, for use with Varian packed column injectors

General description

Version améliorée du septum Thermogreen LB-1 d′origine.
  • Ressuage extrêmement faible sur une large gamme de températures d′injection (de 100 °C à 350 °C).
  • Produit déjà conditionné, prêt à l'emploi.
  • Pénétration de l′aiguille facilitée et grande tolérance aux piqûres (produit idéal pour les passeurs d′échantillons).
  • Formulation de caoutchouc brevetée par Supelco.
Septum is a very important component of syringe injection system. They are usually fabricated from elastomeric, self-sealing materials such as silicone rubber, neoprene or fluoroelastomers. It is suitable to conveniently introducing the sample without causing the system to leak. Improper septa decomposes under the high-temperature conditions of capillary inlets causing baseline disruption and ghost peaks in a chromatogram.

Application

Thermogreen® LB-2 Septa is suitable for the following applications:
  • To minimize extraction onto or loss of analytes off the solid phase microextraction (SPME) fiber from the vial during analysis by GC-MS.
  • Thermo-resistant septa is used in GC instrument to avoid carrier gas leaks, extraneous peaks and phthalate contamination.
  • Thermo-resistant septa along with thick needle protector is used in GC instruments to avoid damage irreversibly caused by microsyringe.
  • It is also used in the influent sampling ports in gas chromatographs.

Other Notes

Si vous utilisiez des tailles de septum de 9mm, nous vous recommandons d′utiliser des septa de 9,5mm

Legal Information

GOW-MAC is a registered trademark of GOW-MAC Instrument Co.
Thermogreen is a registered trademark of Merck KGaA, Darmstadt, Germany


Still not finding the right product?




Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents