39435

Aluminum Standard for AAS

TraceCERT®, 1 g/L Al in nitric acid (nominal concentration)

Synonyme(s) :

Aluminum Atomic Absorption Standard

Se connecter pour consulter les tarifs organisationnels et contractuels.

Sélectionner une taille de conditionnement

Changer de vue

A propos de cet article

NACRES:
NA.24
UNSPSC Code:
41116107
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider


Quality Segment

product line

TraceCERT®

grade

certified reference material, TraceCERT®

concentration

1 g/L Al in nitric acid (nominal concentration)

technique(s)

AAS: suitable

application(s)

cleaning products
cosmetics
environmental
food and beverages
personal care

format

single component solution

General description

This certified reference material (CRM) is produced in accordance with ISO 17034 and characterized in accordance with ISO/IEC 17025. This CRM is traceable to SI unit kg and measured against primary material from a National Metrology Institute (NMI), e.g. NIST.

Please visit ISO certificates and Site Quality Self-Assessments to access the current certificates of accreditation.

Download your certificate at https://www.sigma-aldrich.com to view certified values, including uncertainty and expiry date.

Application

This aluminum standard solution is used as a reference standard to calibrate and validate the analytical method for the determination of aluminum, in lubricating oils by electrothermal atomic absorption spectroscopy.

Analysis Note

1 g/L Al in 2% nitric acid, prepared with high purity Al(NO3)3·9H2O, HNO3 and water

Other Notes

For a complete product listing of our ICP and AAS range, including technical information and example certificates, please visit ICP & AAS standards website.

Detailed information on our complete workflow solutions for ICP-AAS can be found in our Brochure: High-Purity Chemicals for Inorganic Trace Analysis.

In our effort to be more sustainable, we′re going digital with COAs-download them directly from our website.

Legal Information

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany


Pictogrammes

Corrosion

Mot-clé

Danger

Codes de danger

Hazard Classifications

Eye Dam. 1 - Met. Corr. 1 - Skin Irrit. 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

EPI (équipement de protection individuelle)

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter

Classe de stockage

12 - Non Combustible Liquids



Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents