Accéder au contenu
Merck

EZHPYYT

Human PYY ELISA Kit

measures and quantifies total PYY levels in 20 μL serum or plasma

Synonyme(s) :

PYY ELISA Kit

Se connecter pour consulter les tarifs organisationnels et contractuels.

Sélectionner une taille de conditionnement

Changer de vue

A propos de cet article

UNSPSC Code:
12161503
eCl@ss:
32161000
NACRES:
NA.32
Input:
sample type plasma (K2 EDTA)
sample type serum
Species reactivity:
human
Storage temp.:
2-8°C
Shipped in:
wet ice
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider


Nom du produit

Human PYY (Total) ELISA, This Human PYY (Total) ELISA is used to measure & quantify PYY (Total) levels in Metabolism & Endocrine & Neuroscience research.

Quality Segment

species reactivity

human

packaging

kit of 1 × 96 wells

parameter

20 μL sample volume (4hr assay)

technique(s)

ELISA: suitable

input

sample type plasma (K2 EDTA)
sample type serum

NCBI accession no.

UniProt accession no.

application(s)

research use

assay range

accuracy: 83.3-88.9%
(Serum), accuracy: 95.9-102.5%
(Plasma), linearity: 94-99%
(plasma), linearity: 97-105%
(serum), sensitivity: 1.4 pg/mL, standard curve range: 10-2,000 pg/mL, inter-assay cv: 3.7-16.5%
intra-assay cv: 0.9-5.8%
(Plasma), inter-assay cv: 6.1-6.9%
intra-assay cv: 1.5-2.7%
(Serum)

detection method

colorimetric (450nm/590nm)

shipped in

wet ice

storage temp.

2-8°C

General description

Peptide YY (PYY) is a hormone released by the lower GI tract with circulating levels increasing after meals in direct proportion to the caloric content. It is one of the major physiological signals to reduce appetite and food intake. Other functions of PYY are the inhibition of gastric acid secretion, GI motility and pancreatic enzyme output.

Application

3 hour assay using 20 µL sample size ~ Room Temperature
Research Category
Metabolism
Research Sub Category
Obesity

Metabolic Disorders
Used to detect/quantify: PYY (Total)

Biochem/physiol Actions

Human PYY 3-36 100%~Human PYY 1-36 104%~Human [Leu31,Pro34] PYY 138%~Human [Pro34] PYY 158%~Porcine, Canine, Rat, or Mouse PYY Not Detectable

Disclaimer

For research use only. Not for use in diagnostic procedures.


signalword

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Met. Corr. 1 - Repr. 1B - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3

target_organs

Respiratory system

Classe de stockage

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

wgk

WGK 3



Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents