E-060
17β-Estradiol solution
1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
About This Item
Qualité
certified reference material
Niveau de qualité
Forme
liquid
Caractéristiques
Snap-N-Spike®/Snap-N-Shoot®
Conditionnement
ampule of 1 mL
Fabricant/nom de marque
Cerilliant®
Concentration
1.0 mg/mL in acetonitrile
Technique(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
Application(s)
clinical testing
clinical testing
Format
single component solution
Température de stockage
2-8°C
Chaîne SMILES
CC12CCC3C(CCc4cc(O)ccc34)C1CCC2O
InChI
1S/C18H24O2/c1-18-9-8-14-13-5-3-12(19)10-11(13)2-4-15(14)16(18)6-7-17(18)20/h3,5,10,14-17,19-20H,2,4,6-9H2,1H3/t14-,15-,16+,17+,18+/m1/s1
Clé InChI
VOXZDWNPVJITMN-ZBRFXRBCSA-N
Informations sur le gène
human ... ESR1(2099)
Description générale
17β-Estradiol belongs to the group of endogenous endocrine disruptors that disturb thyroid activity and function. It is also a sex hormone prescribed under the trade names Vagifem®, Estring®, Evamist, Elestrin®, Estrace®, and Estrogel® as a treatment for hypoestrogenism.
Application
- Electrochemical determination of 17β-Estradiol in river water samples using a reduced graphene oxide and a metal complex porphyrin-based sensor
- Development of a fluorescence resonance energy transfer (FRET) based aptasensor to determine 17β-Estradiol in environmental water, urine, and milk samples
- Analysis of milk product samples to estimate 17β-Estradiol by high-performance liquid chromatography (HPLC) coupled with fluorescence detection following its solid phase extraction using graphene/multi-walled carbon nanotubes (MWCNTs)
- Solid phase extraction of 17β-estradiol and 17α-ethinylestradiol from tap water samples using magnetic graphene oxide (GO)/γ-Fe2O3 nanoparticles for their simultaneous quantification by high-performance liquid chromatography (HPLC) combined with fluorescence detector
- Multi-residue analysis of 17β-estradiol and 17α-ethinylestradiol in commercial pharmaceutical formulation and urine samples using hanging mercury drop electrode and screen printed carbon electrode
Caractéristiques et avantages
- Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
- Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
- Rigorously tested through real-time stability studies to ensure accuracy and shelf life
- Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
- Flame sealed under argon into ampoules for long-term shelf life
- Offered in a convenient, DEA-exempt format to improve laboratory efficiency
Informations légales
Mention d'avertissement
Danger
Mentions de danger
Classification des risques
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Code de la classe de stockage
3 - Flammable liquids
Classe de danger pour l'eau (WGK)
WGK 2
Point d'éclair (°F)
35.6 °F - closed cup
Point d'éclair (°C)
2 °C - closed cup
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique