20508
Inlet Liner, colonne remplie, pour Agilent®/HP 5700, 5830/40A, 5880A, 5890A
pkg of 5 ea
Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme
About This Item
Produits recommandés
Conditionnement
pkg of 5 ea
Technique(s)
gas chromatography (GC): suitable
L × D.E. × D.I.
91.5 mm × 3.0 mm × 1.8 mm
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Description générale
The liner is the second most important part of the inlet. It is the centrepiece of the inlet system, basically a glass tube between the septum and the column, where the sample is evaporated and brought into the gas phase. There are three most important parameters one should keep in mind while choosing a liner, firstly liner volume, considering a typical liner has a volume of 900μl, secondly liner treatment, one should always use a deactivated liner, so that the glass does not react with the analytes introduced in the liner, thirdly liner design, different designs are available like straight, tapered, baffled and without glass wool and one should be careful enough while choosing the design such that it is compatible with the desired injection mode.
- Longueur 91,5 mm × D.E. 3 mm × D.I. 1,8 mm.
- Remplace la référence du fabricant: 5080-3782
Application
Inlet liner maybe used for the determination and evaluation of volatile components in food products. The vegetable oil maybe directly placed into the GC inlet liner packed with glass wool and then inserted into the heated inlet of the GC for analysis.
Produit comparable
Réf. du produit
Description
Tarif
Faites votre choix parmi les versions les plus récentes :
Certificats d'analyse (COA)
Désolés, nous n'avons pas de COA pour ce produit disponible en ligne pour le moment.
Si vous avez besoin d'assistance, veuillez contacter Service Clients
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Environmental science and pollution research international, 23(20), 20506-20516 (2016-07-28)
Endosulfan is a persistent organic pollutant and widely used in agriculture as a pesticide. It is present in air, water, and soil worldwide; therefore, it is a health risk affecting especially the reproductive system. The aim of this study was
Analysis of vegetable oils for flavor quality by direct gas chromatography.
Journal of the American Oil Chemists' Society, 54 (10), 445-449 (1977)
Fire Debris Analysis.
Science, 249-253 (2007)
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique