Accéder au contenu
Merck
Toutes les photos(1)

Principaux documents

F1056

Sigma-Aldrich

Human Fibronectin

from human plasma, powder, suitable for cell culture

Synonyme(s) :

Fibronectin

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Numéro CE :
Numéro MDL:
Code UNSPSC :
12352202
Nomenclature NACRES :
NA.75
Le tarif et la disponibilité ne sont pas disponibles actuellement.

Nom du produit

Fibronectine, lyophilized powder, BioReagent, suitable for cell culture, ≥95% (SDS-PAGE)

Source biologique

human plasma

Niveau de qualité

Stérilité

sterile

Gamme de produits

BioReagent

Essai

≥95% (SDS-PAGE)

Forme

lyophilized powder

Conditionnement

pkg of 1 mg
pkg of 2 mg
pkg of 5 mg

Technique(s)

cell culture | mammalian: suitable

Couverture de surface

1‑5 μg/cm2

Solubilité

H2O: 1 mg/mL at 37 °C

Numéro d'accès UniProt

Spécificité de la liaison

Peptide Source: Collagen

Conditions d'expédition

dry ice

Température de stockage

−20°C

Informations sur le gène

human ... FN1(2335)

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Fibronectin is a class of high-molecular-weight adhesive glycoprotein,[1] predominant in extracellular matrix (ECM) and is widely distributed in tissue and blood. The FN gene, which is highly conserved, gives rise to a minimum of 20 isoforms through alternative splicing in humans. These isoforms include notable variants such as cellular FN and plasma FN.[2] Plasma FN is primarily synthesized in the liver, whereas cellular FN which represents only 5% of the circulating fibronectins[3] is locally produced by various cell types.[2]

Application

Fibronectin human plasma has been used:
  • in neural selection medium to coat tissue culture surface for neuronal differentiation[4]
  • to coat culture vessels for characterization of iPSC and iPSC‑derived BMEC in 2D cell culture[5]
  • to coat culture supports for endothelial cell culture[6]

Actions biochimiques/physiologiques

Fibronectin plays a major role in biological processes. It interacts with surface receptors and other major ECM proteins like collagen to mediate cellular signals.[2] Fibronectin is involved in a variety of cellular functions, including adhesion, cytoskeletal organization, oncogenic transformation, cell migration, phagocytosis, hemostasis, and embryonic differentiation.[3] This glycoprotein can bind to integrins, collagens, fibrins and glycosaminoglycans (GAGs).[1] FN plays a crucial role in promoting cell cycle progression and proliferation. This interaction influences cyclins and immediate early response genes, contributing to cellular processes related to cell division and growth. FN is also involved in cell survival and protection from apoptosis in various cell types, including epithelial and endothelial cells and leukocytes. FN serves as a critical factor in promoting cell survival and preventing programmed cell death in these cellular contexts.[7] Mutations in the FN gene are associated with FN glomerulopathy and spondylometaphyseal dysplasia.[2] Fibronectin plays a significant role in the wound healing process, and in extracellular matrix (ECM) assembly, hence is considered suitable for tissue engineering applications.[1]

Attention

The reconstituted solution should be stored in working aliquots at -20°C or lower. Vortexing, excessive agitation, or additoinal freezing and thawing of reconstituted fibronectin are not recommended.

Notes préparatoires

This product is lyophilized from 0.05 M Tris buffered saline at pH 7.5. It is soluble at 1 mg/mL in water, and should be allowed to dissolve for at least 30 minutes at 37°C. A small amount of undissolved material may remain, but it will not affect performance. The protein homogeneity is evaluated by immunoelectrophoresis, is endotoxin tested, and the source material was tested negative for HIV, hepatitis B and hepatitis C.

In coating culture surfaces, fibronectin should be diluted in sterile balanced sterile salt solution and coated with minimal volume. Surface should then be air dried for 45 minutes at room temp and can be stored for 2-4 weeks at 2-8°C.

Clause de non-responsabilité

Ce produit, destiné à la recherche scientifique, est soumis à une réglementation spécifique en France, y compris pour les activités d′importation et d′exportation (Article L 1211-1 alinéa 2 du Code de la Santé Publique). L′acheteur (c′est-à-dire l′utilisateur FINAL) est tenu d′obtenir une autorisation d′importation auprès du ministère français de la recherche, mentionné à l′article L1245-5-1 II du Code de la Santé Publique. En commandant ce produit, vous confirmez détenir l′autorisation d′importation requise.

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

Eyeshields, Gloves, type N95 (US)


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Fibronectin
Fabrizio M and Angela S
Encyclopedia of Immunology, 909-913 (1998)
Vivek V Thacker et al.
eLife, 9 (2020-11-25)
We establish a murine lung-on-chip infection model and use time-lapse imaging to reveal the dynamics of host-Mycobacterium tuberculosis interactions at an air-liquid interface with a spatiotemporal resolution unattainable in animal models and to probe the direct role of pulmonary surfactant
Artificial biomaterials for urological tissue engineering
Farhat WA and Geutjes, PJ
Journal of Separation Science (2009)
Jianfei He et al.
Redox biology, 36, 101631-101631 (2020-08-19)
Anastellin (AN), a fragment of the first type III module in fibronectin (FN), initiates formation of superfibronectin, a polymer which resembles the native cell-derived fibrillar FN found in the extracellular matrix of many tissues, but which displays remarkably different functional
Floriana Burgio et al.
Cellular and molecular neurobiology, 43(8), 4173-4187 (2023-09-12)
Delivering biologics to elicit a therapeutic response in the central nervous system (CNS) remains challenging due to the presence of the blood-brain barrier (BBB). Receptor-mediated transcytosis is a strategy to improve brain exposure after systemic drug administration. The availability of

Articles

Extracellular matrix proteins such as laminin, collagen, and fibronectin can be used as cell attachment substrates in cell culture.

Extracellular matrix proteins such as laminin, collagen, and fibronectin can be used as cell attachment substrates in cell culture.

Extracellular matrix proteins such as laminin, collagen, and fibronectin can be used as cell attachment substrates in cell culture.

Extracellular matrix proteins such as laminin, collagen, and fibronectin can be used as cell attachment substrates in cell culture.

Protocoles

Diluer la fibronectine à la concentration souhaitée. Les conditions d'adhésion optimales dépendent du type de cellules et de l'application. La concentration de coating standard varie de 1 à 5 µg/cm2. Protocole de coating de fibronectine, produits et FAQ.

Diluer la fibronectine à la concentration souhaitée. Les conditions d'adhésion optimales dépendent du type de cellules et de l'application. La concentration de coating standard varie de 1 à 5 µg/cm2. Protocole de coating de fibronectine, produits et FAQ.

Diluer la fibronectine à la concentration souhaitée. Les conditions d'adhésion optimales dépendent du type de cellules et de l'application. La concentration de coating standard varie de 1 à 5 µg/cm2. Protocole de coating de fibronectine, produits et FAQ.

Dilute fibronectin for cell attachment, varying per cell type. Coating protocol, products, and FAQs provided.

Afficher tout

Questions

1–10 of 11 Questions  
  1. What is the molecular weight of this product?

    1 answer
    1. Human fibronectin is composed of two nearly identical disulfide bound peptides. Each has a molecular weight of 220 kDa for a combined total of 440 kDa.

      Helpful?

  2. This is to ask a question regarding coating flasks with the human freeze-dried fibronectin (F1056). After dissolving it in sterile water and diluting to the desired concentration should I incubate the flasks at 4 or 37 degrees overnight? Many thanks!

    1 answer
    1. As noted in the DESCRIPTION section of the Product Detail Page, fibronectin should be diluted in a sterile balanced sterile salt solution and coated with minimal volume. The surface should then be air dried for 45 minutes at room temp and can be stored for 2-4 weeks at 2-8°C. See the information below for a brief protocol:

      To coat culture surfaces:
      1. Dilute fibronectin in a sterile balanced salt solution
      and coat the culture surface (1-5 mg/cm2) with a
      minimal volume.
      2. Allow to air dry for at least 45 minutes at room
      temperature, Excess fibronectin may be removed
      by aspiration, but this is not necessary.
      3. Fibronectin coated cultureware can be stored for
      2-4 weeks at 2-8 °C in a closed sterile container or
      sterile sealable bags.

      Helpful?

  3. How do I solubilized Fibronectin?

    1 answer
    1. Dissolve at 1 mg/mL in water. Allow to dissolve for at least 30 minutes at 37 °C. A small amount of undissolved material may remain. This will not affect product performance.

      Helpful?

  4. How do I choose which fibronectin product to use to coat culture surfaces for cell growth?

    1 answer
    1. The species source for the fibronectin used when coating culture surfaces is not important.  It is the presence of the RGD binding site that is present in all fibronectins that promotes binding.

      Helpful?

  5. How long can I store the fibronectin solution?

    1 answer
    1. The product is good for at least a year at 2-8 °C if kept sterile.

      Helpful?

  6. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  7. How do I determine how much fibronectin is in solution?

    1 answer
    1. As the product may contain undissolved material, the amount of fibronectin in solution can be determined by UV absorbance.  The extinction coefficient for a 1% solution (10 mg/ml) is 13.5 at 280 nm.

      Helpful?

  8. How do I test the wells/flasks that have been coated with fibronectin?

    1 answer
    1. We test the coated culture surface by culturing cells.  We compare the adherence of the cells to wells that have been coated with media containing BSA (negative) and media containing 10% FBS (positive).  The cell growth should be not less than 50% of the positive control and greater than 50% of the negative control.

      Helpful?

  9. What is the difference between Fibronectin Products F2006 and F1056?

    1 answer
    1. The difference between Product Nos. F2006 and F1056 is in the purity specifications and endotoxin testing.  Product  No. F2006 has a purity specification of ≥90% and is not tested for endotoxin contamination.  Product No. F1056 has a purity specification of ≥95% and is tested for endotoxin contamination with a specification of ≤100 EU/mg.

      Helpful?

  10. What is the procedure for coating culture surfaces with fibronectin?

    1 answer
    1. To coat culture surfaces: 1. Dilute fibronectin in sterile balanced salt solution and coat the culture surface (1-5 μg/cm2) with a minimal volume.  2. Allow to air dry for at least 45 minutes at room temperature.  Excess fibronectin may be removed by aspiration, but this is not necessary.

      Helpful?

1–10 of 11 Questions  

Reviews

No rating value

Active Filters

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique